Central Heating
Max. rated heat output net 40/30°C
Max. rated heat output net 50/30°C
Max. rated heat output net 80/60°C
Max. rated heat input net
Min. rated heat output net 40/30°C
Min. rated heat output net 50/30°C
Min. rated heat output net 80/60°C
Min. rated heat input net
Max. flow temperature
Max. permissible operating pressure
Gas flow rate - Max. 10 minutes from lighting
Natural Gas G20
Propane Gas (LPG)
Gas supply pressure
Natural Gas G20
LPG (Propane) Gas G31
Flue
Flue Gas Temp. 80/60°C, rated min. load
Flue Gas Temp. 40/30°C, rated min. load
CO
level at max. rated heat output
2
CO
level at min. rated heat output
2
NO
- classification
x
Condensate
Max. condensation rate
pH value, approx.
Electrical
Electrical power supply voltage
Frequency
Max. power consumption (without pump)
General Data
SEDBUK (Band A)
Appliance protection rating
Permissable ambient temperatures
Nominal capacity of appliance
Noise output level (at maximum CH output)
Weight (excluding packaging)
4

TECHNICAL DATA

TECHNICAL DATA
UNITS
Natural Gas
FS 30CDi
FS 42CDi
kW
32.1
kW
31.8
kW
30
kW
30.9
kW
8.6
kW
8.6
kW
7.7
kW
8
°C
88
bar
2.65
m
/h
3.27
3
kg/h
-
mb
20
mb
-
°C
67/55
°C
43/32
%
9.4
%
8.6
class
5
l/h
2.7
4.8
AC...V
230
Hz
50
W
60
%
90.5
IP
x4D
°C
0 - 50
Itr
3.75
dB(A)
37
kg
55.1
INSTALLATION & SERVICING INSTRUCTIONS
8 716 115 216b (09.2008)
L.P.G
FS 30CDi
FS 42CDi
43.7
32.1
43.7
43.3
31.8
43.3
40.8
30
40.8
42
30.9
10.8
11.6
13.5
10.7
11.4
13.4
9.6
10.5
12.0
10
10.8
12.5
88
88
2.65
2.65
2.65
4.4
-
-
2.3
3.3
20
-
37
67/55
67/55
67/55
43/32
43/32
43/32
9.4
10.8
10.8
9.0
10.4
10.4
5
5
3.7
2.7
3.7
4.8
4.8
4.8
230
230
230
50
50
80
60
90.3
91.9
91.1
x4D
x4D
x4D
0 - 50
0 - 50
0 - 50
3.75
3.75
3.75
37
37
55.1
55.1
55.1
42
88
-
37
5
50
80
37

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Greenstar FS 30CDi Regular and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Greenstar fs 30cdiGreenstar fs 42cdi

Table of Contents