Worcester Greenstar FS 30CDi Regular Instruction Manual page 41

Worcester floor standing rsf gas-fired condensing regular boiler
Table of Contents

Advertisement

A
B
H
INSTALLATION & SERVICING INSTRUCTIONS
8 716 115 216b (09.2008)
REPLACEMENT PARTS
Sensors:
Check that the appliance is electrically
isolated.
Flow temperature sensor (A):
Remove the connector.
Release the sensor clip and withdraw
the sensor.
Apply heat transfer paste to the
replacement sensor.
Safety temperature limiter (B):
Remove the connectors.
Unscrew the sensor.
Flue Temperature limiter (H):
Remove the connector.
Unscrew the sensor.
REPLACEMENT PARTS
39