9. FIELD ELECTRICAL CONNECTIONS MATCHING

- Connect the power supply to the outdoor unit and then get the power required for the indoor unit from the outdoor unit.
- Refer to wiring diagrams and stickers-caution sticked inside the outdoor & indoor units.
9-1 CONNECTING ELECTRICAL WIRING FOR HEAT PUMP SYSTEM
LEGEND
Earth
L
Live power supply.
N
Neutral power supply.
R
Live connection indoor/outdoor unit.
C
Neutral connection indoor/outdoor unit.
Y
Compressor control.
O
Reversing valve control.
W2
Outdoor fan motor control.
S
Outdoor coil sensor.
Sizes of electrical wires connecting outdoor and indoor units
R
1 mm
9-2 CONNECTING ELECTRICAL WIRING FOR COOL ONLY SYSTEM
LEGEND
Earth
L
Live power supply.
N
Neutral power supply.
R
Live connection indoor/outdoor unit.
C
Neutral connection indoor/outdoor unit.
Y
Compressor control.
Sizes of electrical wires connecting
outdoor and indoor units
R
C
1 mm
1 mm
2
C
1 mm
1 mm
2
2
Y
1 mm
2
2
Indoor Unit
Y
O
1 mm
2
2
Indoor Unit
R
C
R
C
8
Circuit
Breaker
Outdoor
Unit
W2
S
1 mm
1 mm
2
2
Y
Circuit
Breaker
Y
Outdoor
Unit
Main
Switch
Main
Switch

Hide quick links: