MODELS: WD-60C9 / WD-65C9 / WD-73C9 / WD-60737 / WD-65737 / WD-73737 / WD-82827

Manual Geometry Alignment

1.
Activate the Service Mode <MENU><2-4-5-7>. From the Service Menu, press the <0> button. The Data
Transfer & Geometry Menu will appear.
2.
Use the <
> buttons to select "MANUAL GEOMETRY ALIGNMENT" and press <ENTER>.
The Manual Keystone Geometry Alignment Pattern will appear. See below.
Note:
To remove all geometry correction, while the Geometry Alignment Pattern is displayed, press <1> then
<ENTER>. This will null all correction data. Then re-enter the Manual Geometry Alignment
step 2.
Note: To restore the original factory correction data, select "RESTORE GEOMETRY DATA FROM BACKUP" and
press <ENTER>.
Data Transfer & Geometry Menu <MENU><2-4-5-7><0>
RESTORE ENGINE DATA FROM BACKUP
RESTORE GEOMETRY DATA FROM BACKUP
MANUAL GEOMETRY ALIGNMENT
RESTORE INDEX DELAY
SAVE ENGINE AND GEOMETRY SETTING TO BACKUP
Warning - Only use "SAVE ENGINE AND GEOMETRY SETTING TO BACKUP"
after Optical Engine replacement.
Cursor +
+
Phase 1 - 16 Point Geometry Alignment
1.
16 Adjustment Points are indicated by white dots around the edge of the raster. The adjustment position is
indicated by a + cursor.
2.
Starting from the upper left corner, use the <
flush with the bezel as a reference. See example above.
Note: Only the cursor will move. The Geometry Pattern will not change.
3.
After adjusting each point, use the <
until all 16 points have been adjusted.
4.
After all 16 points are adjusted and the cursor is returned to the original starting point, press <ENTER>.
Correction will be automatically calculated and saved and the Manual Geometry Alignment will be terminated.
5.
Press <ENTER> to re-activate the Manual Geometry Alignment. The geometry pattern will appear with the
corrections applied.
WD-65837 / WD-73837 / WD-82837
Align Cursor + Flush With Bezel Edge
> button to shift the cursor to the next point clockwise and repeat