Mitsubishi Electric WD-60C9 Service Manual page 12

Dlp projection hdtv v41c, v41 & v41+ chassis
Hide thumbs Also See for WD-60C9:
Table of Contents

Advertisement

MODELS: WD-60C9 / WD-65C9 / WD-73C9 / WD-60737 / WD-65737 / WD-73737 / WD-82737
OPTICAL ENGINE REPLACEMENT (Continued)
B
DUCT INTERIOR COMPONENTS
1) Figure 3 shows the Duct Interior Components.
2) The Upper Duct must be removed to replace the Lamp Door Switch PWB, Sirocco Fan, Exhaust Fan and
Thermal Sensor (1 screw).
3) When replacing the Engine, transfer the Duct Interior Components from old Engine to the new Engine.
Note: There are three Exhaust Fan Holders, one on the top and two on the bottom of the Exhaust Fan.
Note: The Exhaust Fan must be installed so the Label is facing inside the Duct.
Note: The Sirocco Fan must be installed so the Label is facing upwith the Flanges aligned onto the Guide Pins.
FLANGES Align
Onto GUIDE PINS
WD-65837 / WD-73837 / WD-82837
Latch
Latch
Figure 2: Duct Assembly (Top View)
THERMAL
SENSOR
(Behind Lamp Housing)
LAMP DOOR
SWITCH
Figure 3: Lower Duct (Top View)
Page 12
Latches
EXHAUST FAN
HOLDERS (3)
(1 Top - 2 Bottom)
SIROCCO FAN
(Label Facing Up)
PWB
EXHAUST
FAN
(Label Facing Inside)