3. LEAD IN AND LEAD OUT ADJUSTMENT
(1) Lead in
(Test record: Hitachi HT-5 (30cm))
Check that the stylus lowers at 5 to 25 counts for both
17cm and 30cm records.
(2) Lead out
(Test record: Nippon Columbia EM-1001
(17cm))
Check that the pickup returns at 3 to 15 counts (3mm
pitch).
If the counts are off , adjust as follows:
(a) Fasten the pickup to the arm rest.
(b) Detach the Bottom board.
(c) Insert a screwdriver into the lead in or lead out
adjustment parts and adjust.
(d) After adjustment, fix it in Three Bond 1401B.
(e) Fix the Bottom board.
Lead in
• Count increases when turned clockwise
• Count decreases when turned counterclockwise
Lead out
• Count increases when turned clockwise
• Count decreases when turned counterclockwise
Lead in adjust part
Lead out adjust part