Maintenance M A N U A L C H Â T E A U S E R I E S R A NGES & COOKTOPS « Centenaire » Grand Palais 180 Château 165 Château 150 Château 120 Château 90 Château 75...
O NOT STORE ITEMS OF INTEREST TO CHILDREN IN CABINETS ABOVE A RANGE OR ON THE BACKGUARD OF A RANGE CHILDREN CLIMBING ON THE RANGE TO REACH ITEMS COULD BE SERIOUSLY INJURED LA CORNUE Page Installation Guide Château Series Centenaire 08NOTINSTAL100/USA-6...
Page 4
- Be sure your appliance is properly instal led and grounded by a qualified technician. The instal lation of your La Cornue appliance must conform with local codes or, in the absence of local codes, in the USA with the "National Fuel Gas Code", ANSI Z223.1NFPA 54, latest edition, and, in Canada, with CAN/CGA...
Al l our cooking appliances are intended for domestic use only; i.e., not profes- sional. In the event of non-domestic use, the manufacturer shal l not incur any liability, and the warranty shal l be considered void. LA CORNUE Page Installation Guide Centenaire...
Page 6
- When flaming foods under the hood, turn the fan on. u Do not use air recycling systems. u “La Cornue” can provide customers with hoods in materials matching the appliance. The hoods are sold without blower systems since every instal lation is unique.
Page 7
Proper relationship of utensil to burner wil l also improve efficiency. u The top burner flame size should be adjusted so it does not extendbeyond the edge of the cooking utensil. This instruction is based on safety considerations. LA CORNUE Page Installation Guide Centenaire 08NOTINSTAL100/USA-6...
Page 8
Flammable materials should not be stored in an oven, the range storage drawer or near the cooktop burners. This includes paper, plastic and cloth items, such as cookbooks, plasticware and towels, as wel l as flam- LA CORNUE Page Installation Guide Centenaire...
Page 9
(LP) fuels. Properly adjusted burners wil l minimize incomplete combustion. LA CORNUE Page Installation Guide Centenaire 08NOTINSTAL100/USA-6...
Page 10
Birds have a very sensitive respiratory system. Fumes released due to overheated cooking oil, fat, margarine and overheated non-stick cookware may be harmful. You can find this manual on fol lowing web sites: www.lacornueusa.com www.purcel lmurray.com www.lacornue.com/ca www.agamarvel.com LA CORNUE Page Installation Guide Centenaire 08NOTINSTAL100/USA-6...
Page 11
Le Château 150 Dear Customer, Thank you for choosing the La Cornue cooking product. We hope that you will derive a lot of enjoyment from cooking delicious meals with it. The aim of this document is to make you familiar with the potential provided by a professional quality product designed for discriminating individuals, and to facilitate its maintenance.
AFETY NSTRUCTIONS ............. 1 ......................11 ESCRIPTION 1. Le Grand Palais 180 ..................12 2. Le Château ® 165 ..................15 3. Le Château ® 150 ..................18 4. Le Château ® 120 ..................22 5. Le Château ® 90 .................... 26 6.
Description ESCRIPTION The La Cornue “Château Centenaire” series consist of 6 models of stoves and hobs: 7 /8 - Le Grand Palais 180, width 70 “ (1,800 mm). - Le Château 165, width 65“ (1,650 mm). - Le Château 150, width 59“ (1,500 mm).
R A N D A L A I S The "Le Grand Palais 180" range, one of the models of the "La Cornue" series consists of: — 2 thermostatically-controlled large vaulted ovens, gas and electric (only ranges). — One cooktop bounded at the rear by a stainless steel backsplash creating a gap between the range and the wall, thus ensuring the removal of burnt gases and smells (ranges and cooktops).
Page 16
Le Grand Palais 180 ESCRIPTION For each gas type and for each model, the tables below summarize the total electric power (W) and the input ratings (BTU/hr). LECTRIC SUPPLY INFORMATION AS SUPPLY INFORMATION LA CORNUE Page Installation Guide Centenaire 08NOTINSTAL100/USA-6...
E S C R I P T I O N H ÂT E AU The "Le Château 165" range, one of the models of the "La Cornue" series consists of: — 2 thermostatically-controlled vaulted ovens, 1 large gas oven and 1 small electric oven (only ranges).
Page 19
® Le Château ESCRIPTION For each gas type and for each model, the tables below summarize the total electric power (W) and the gas input ratings (BTU/hr). LECTRIC SUPPLY INFORMATION AS SUPPLY INFORMATION LA CORNUE Page Installation Guide Centenaire 08NOTINSTAL100/USA-6...
E S C R I P T I O N H ÂT E AU The "Le Château 150" range, one of the models of the "La Cornue" series consists of: — 2 thermostatically-controlled smal l vaulted ovens, gas and electric (only ranges).
Page 22
Le Château ® ESCRIPTION For each gas type and for each model, the tables below summarize the total electric power (W) and the gas input ratings (BTU/hr). LECTRIC SUPPLY INFORMATION LA CORNUE Page Installation Guide Centenaire 08NOTINSTAL100/USA-6...
Page 23
Le Château ® ESCRIPTION AS SUPPLY INFORMATION LA CORNUE Page Installation Guide Centenaire 08NOTINSTAL100/USA-6...
E S C R I P T I O N H ÂT E AU The "Le Château 120" range, one of the models of the "La Cornue" series consists of: — 2 thermostatically-controlled smal l vaulted ovens, gas and electric (only ranges).
Page 26
Le Château ® ESCRIPTION For each gas type and for each model, the tables below summarize the total electric power (W) and the gas input ratings (BTU/hr). LECTRIC SUPPLY INFORMATION LA CORNUE Page Installation Guide Centenaire 08NOTINSTAL100/USA-6...
Page 27
Le Château ® ESCRIPTION AS SUPPLY INFORMATION LA CORNUE Page Installation Guide Centenaire 08NOTINSTAL100/USA-6...
E S C R I P T I O N H ÂT E AU The "Le Château 90" range, one of the models of the "La Cornue" series consists of: — 1 thermostatically-controlled large vaulted oven, gas or electric (only ranges).
Page 30
Le Château ® ESCRIPTION For each gas type and for each model, the tables below summarize the total electric power (W) and the gas input ratings (BTU/hr). LECTRIC SUPPLY INFORMATION LA CORNUE Page Installation Guide Centenaire 08NOTINSTAL100/USA-6...
Page 31
Le Château ® ESCRIPTION AS SUPPLY INFORMATION LA CORNUE Page Installation Guide Centenaire 08NOTINSTAL100/USA-6...
E S C R I P T I O N H ÂT E AU The "Le Château 75" range, one of the models of the "La Cornue" series consists of: — 1 thermostatically-controlled smal l vaulted oven, gas or electric (only ranges).
Page 34
Le Château ® ESCRIPTION For each gas type and for each model, the tables below summarize the total electric power (W) and the gas input ratings (BTU/hr). LECTRIC SUPPLY INFORMATION AS SUPPLY INFORMATION LA CORNUE Page Installation Guide Centenaire 08NOTINSTAL100/USA-6...
The use of a gas cooking appliance results in the production of heat and moisture in the room in which it is installed. It is essential that the kitchen where the "La Cornue" stove will be installed has excellent ven- tilation to the outside, for vapor and combustion gases, and a fresh air inlet.
The tables in pages 14, 17, 20, 24, 28 and 32 show the necessary power and amp ratings for each La Cornue model. The power of the "La Cornue" stoves, does not al low for a simple plug and socket connection; the electrical connection must be made by means of an adequate flexible cord, built-in junction box, with terminal blocks;...
2. Remove oven doors by engaging the latches on the hinges and by pulling the door back and up. 3. Remove the plinthes/toe-kicks using a standard screwdriver. Full view of elements set aside. Installation Guide Centenaire LA CORNUE Page 08NOTINSTAL100/USA-6...
Page 38
6. When lifting up stairs, the straps of the handlers at the bottom should be shorter so the cooker stays level. The back of the cooker should always face the inside side of the ramp. Installation Guide Centenaire LA CORNUE Page 08NOTINSTAL100/USA-6...
Remove the drawers and plinthes/toe-kicks, set the cooker in place, screw up the central legs so the cooker rests on the outside legs and adjust the height. Once the cooker is resting at the right height and is level, screw down the central legs to balance the weight. Installation Guide Centenaire LA CORNUE Page 08NOTINSTAL100/USA-6...
O N N E C T I O N S O N N E C T I O N S This appliance must be instal led by a qualified La Cornue professional in accordance with the current regulations in the country where the appliance is instal led.
16,501 – 22,500 Only a 4 wire cord is to be used when the appliance is installed where grounding through the neutral conductor is prohibited, such as: - new branch-circuit installations (1996 NEC), Installation Guide Centenaire LA CORNUE Page 08NOTINSTAL100/USA-6...
Page 42
4 ft (1.2 m) length. The range can then be easily disconnected for servicing. The "La Cornue" appliance is supplied with a connection terminal block accessible by unscrewing the stainless steel protection plate on the backside.
3. G AS CONNECTION The instal lation of your La Cornue appliance must conform with local codes or, in the absence of local codes, in the USA with the “National Fuel Gas Code”, ANSI Z223.1, latest edition, and, in Canada, with CAN/CGA - B149.1, and CAN CGA - B149.2, “Instal lation Code for Gas Burning Appliances”.
Page 44
The gas regulator on the appliance is set at the factory for pressures given by regulations. For the La Cornue ranges and hobs the regulator and the pressure tap can be found on the hob’s manifold located by the 2 left gas burners...
Inform the consumer of the location of the gas shut-off valve. The burners on the stoves of the "La Cornue" line are fitted with safety thermocouples: should a burner extinguish, the gas supply to this burner is automatical ly cut off.
Do not touch before they have cooled. 2.3. Electric broiler (gas or electric oven) - The level of the broiler is controlled by the upper knob (D). The green indicator light goes on. After use, turn knob to "0". Installation Guide Centenaire LA CORNUE Page 08NOTINSTAL100/USA-6...
The knob have 3 marked positions ranging from warm (number 1) to very hot (number 3). The largest of the two plates is the most powerful and is the one we suggest using when cooking with large pans. Installation Guide Centenaire LA CORNUE Page 08NOTINSTAL100/USA-6...
This equipment is design-certified by a Nationally Recognized Testing Laboratory to the appropriate National Standards as indicated on the Equipment Rating Plate. Any modification without written permission of the La Cornue Company voids the certification and warranty of this equipment. Your selection of L...
The orifices size depends on the type of gas. The table below is provided for you to determine which orifice should be used if the type of gas is changed. Installation Guide Centenaire LA CORNUE Page 08NOTINSTAL100/USA-6...
Page 50
5. Then block the adjusting cone (2) with the blocking washer (3). Once you have changed the injectors, it is a good idea to adjust the low settings for the hob burners (see Section 1). Installation Guide Centenaire LA CORNUE Page 08NOTINSTAL100/USA-6...
When servicing or replacing gas-carrying components disconnect from gas before commencing operation. Use the correct orifices for high altitude given by La Cornue service only for your appliance. When you have completed the changes, check the appliance is gas sound.
Remove the protection glass and then unscrew the damaged light. Refit a new light and the protection glass. Technical characteristics of the light: - 25W - 230V - 240V - 300°C - E14 base Installation Guide Centenaire LA CORNUE Page 08NOTINSTAL100/USA-6...
“CAUTION - Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.” “Verify proper operation after servicing.” BURNER BURNER BURNER BURNER BURNER BURNER 14 kV 240 V a.c. Installation Guide Centenaire LA CORNUE Page 08NOTINSTAL100/USA-6...
Electrical diagrams AINTENANCE 2. E LECTRIC COOKTOP SECTION WHEN PROVIDED “CAUTION - Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.” “Verify proper operation after servicing.” Installation Guide Centenaire LA CORNUE Page 08NOTINSTAL100/USA-6...
AS OVEN WIRING LECTRONIC IGNITION “CAUTION - Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.” “Verify proper operation after servicing.” Pressure Gas inlet regulator Burner Installation Guide Centenaire LA CORNUE Page 08NOTINSTAL100/USA-6...
Electrical diagrams AINTENANCE 4. E LECTRIC OVEN “CAUTION - Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.” “Verify proper operation after servicing.” Installation Guide Centenaire LA CORNUE Page 08NOTINSTAL100/USA-6...
Warranty ARRANTY La Cornue company warrants to the original user for a service agency of Company except that such period of three years from date of delivery not to obligation to bear labor charges shall not apply to exceed 42 months from date of shipment by Company...
14, rue du Bois du Pont - Z.I. les Béthunes 95310 Saint-Ouen l'Aumône - FRANCE Phone: + 33 (0)1 34 48 36 36 - Fax: + 33 (0)1 34 64 32 65 Postal address: La Cornue SAS - B.P. 99006 95070 Cergy Pontoise Cedex - FRANCE www.lacornue.com e-mail: a.table@la-cornue.com...
Need help?
Do you have a question about the Grand Palais 180 and is the answer not in the manual?
Questions and answers