LG 47LA790V Service Manual page 14

Chassis : ld34d
Table of Contents

Advertisement

3.3. LAN Inspection
3.3.1. Equipment & Condition
▪ Each other connection to LAN Port of IP Hub and Jig
3.3.2. LAN inspection solution
▪ LAN Port connection with PCB
▪ Network setting at MENU Mode of TV
▪ Setting automatic IP
▪ Setting state confirmation
→ If automatic setting is finished, you confirm IP and MAC
Address.
3.3.3. WIDEVINE key Inspection
- Confirm key input data at the "IN START" MENU Mode.
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
3.4. LAN PORT INSPECTION(PING TEST)
Connect SET → LAN port == PC → LAN Port
SET
3.4.1. Equipment setting
(1) Play the LAN Port Test PROGRAM.
(2) Input IP set up for an inspection to Test Program.
*IP Number : 12.12.2.2
3.4.2. LAN PORT inspection(PING TEST)
(1) Play the LAN Port Test Program.
(2) Connect each other LAN Port Jack.
(3) Play Test (F9) button and confirm OK Message.
(4) Remove LAN cable.
3.5. Model name & Serial number Download
3.5.1. Model name & Serial number D/L
Press "Power on" key of service remote control.
(Baud rate : 115200 bps)
Connect RS-232C Signal to USB Cable to USB.
Write Serial number by use USB port.
Must check the serial number at Instart menu.
3.5.2. Method & notice
(1) Serial number D/L is using of scan equipment.
(2) Setting of scan equipment operated by Manufacturing
Technology Group.
(3) Serial number D/L must be conformed when it is produced
in production line, because serial number D/L is mandatory
by D-book 4.0.
- 14 -