DMR-ES30VEG / DMR-ES30VEC / DMR-ES30VEB
Mode name
Production Date Display Display the date when the unit was produced.
Display the accumulated
working time
Display the Error History Display the Error History stored on the unit.
Delete the Error History
AV4 (V) / AV1 (RGB) I/O
Setting
AV2 (Y/C) / AV1 (V) I/O
Setting
AV2 (V) / AV1 (Y/C) I/O
Setting
AV2 (RGB) / AV1 (V) I/O
Setting
P50 (H) Output
Item
Description
Display the accumulated unit s working time.
Delete Error History information stored on
the unit.
Set input to AV4(V) and set output to
AV1(RGB) for I/O checking
Set input to AV2(Y/C) and set output to
AV1(V) for I/O checking
Set input to AV2(V) and set output to
AV1(Y/C) for I/O checking
Set input to AV2(RGB) and set output to
AV1(V) for I/O checking
Timer Microprocessor IC7501-22 output
High signal for AV1-pin 10 passing through
inverter (approx. 0V DC at AV1-pin 10).
FL display
YYY: Year
MM: Month
DD: Day
(Indicating unit: Second)
Display reason of error for 5
seconds.
Display the time when the error
has occurred for 5 seconds.
Y: Year
MM: Month
DD: Day
HH: Hour
MM: Minute
Accumulated working time till
occurring of the error is left
displayed.
(Indicating unit: Second)
When OK.
When NG.
24
Key operation
(Remote controller key)
Press [6] [1] in service mode.
Press [6] [4] in service mode.
Press [6] [5] in service mode.
Then press [0] [1] ~ [1] [9], the past
19 error histories are displayed.
Press [9] [7] in service mode.
Press [8] [0] in service mode.
Press [8] [1] in service mode.
Press [8] [2] in service mode.
Press [8] [3] in service mode.
Press [8] [4] in service mode.