Download Print this page

Installation; Site Selection - Indeeco Quartzone Owner's Manual

Infrared quartz tube & metal sheathed electric heaters

Advertisement

INSTALLATION

These infrared heaters are designed for comfort
are to be permanently mounted to the wall or ceiling with the
fixture directed to the area to be heated. The unit is designed to
give years of safe, trouble-free operation when properly installed,
operated and maintained.
A. Site Selection:
The supporting structure where the heater is attached must have
adequate strength to safely support the heater. This heater has
been evaluated by UL for outdoor use only if mounted
underneath an overhang using a quartz tube heating element.
The heaters should not be mounted close to insulation, drapery
or similar materials which could come in contact with the cabinet
or heater guard. The heaters are intended for elevated mounting
locations so that they radiate down to the floor area. A mounting
height should be selected so that the heater has adequate
clearance to moving equipment and personnel, yet low enough to
deliver heat to the selected area. For heater weights and
minimum clearances, see tables 3 & 4:
TABLE 3:
Fixture
Length
1154
36"
(914mm)
1154A
61"
(1549 mm)
TABLE 4:
Location
Top of heater to ceiling
Bottom of heater to floor
Side or end of heater to wall
Heater to Adjacent Heater
Face of Heater to any
possible combustibles
Once an acceptable location has been determined, see the
following instructions to complete the mechanical installation:
B. Element Installation / Handling:
1.
The heater fixture is shipped as an assembly with very
fragile quartz or metal sheathed heating elements
factory installed.
2.
Replacement elements must be ordered separately to
be installed by a qualified person. See Section:
REPLACEMENT ELEMENT contained in this manual.
CAUTION: Do not handle the Quartz tube heating elements
with bare hands or with gloves that may have grease or oil
present.
C. Heater Mechanical Installation
Chain Mounting:
1. Fasten the two triangular mounting plates to
heating.
They
Max
Weight
Watts
2000
10 lbs
(4.5kg)
4000
13 lbs
(5.9kg)
Minimum
Clearance
12 in
(305 mm)
6 ft
(1.83 m)
12 in
(305 mm)
36 in
(914 mm)
36 in
(914 mm)
the fixture with the screws provided. The dimple hole
should be kept towards the top.
2. Cut suspension chain to the desired length.
3. Attach the chain to the heater triangular brackets using
"S" hooks. S-hooks must be closed to assure the
heater is permanently mounted. Ensure heating
element is horizontal.
4. If desired, tilt heater by adjusting chains as shown in
figure 1:
Bracket Mounting (Item HX-1025662):
The heaters may also be mounted by means of an optional
ceiling or wall mounting bracket as shown in figures 2, 3 &
4
The brackets will register on studs or joists at 16"
centers. For the 36"
mounted with the flanges facing inward and the heater
triangular brackets located on the outer side as shown in
figure 3:
MOUNTING
BRACKET
HEATER
TRIANGULAR
BRACKET
Page 3 of 6
FIGURE 1:
FIGURE 2:
(406mm)
heater, the brackets should be
(914mm)
FIGURE 3:
HEATER
59-2000-83

Advertisement

loading