Electronic Parts - LG AS-W096ERH0 Svc Manual

Universal air conditioner
Hide thumbs Also See for AS-W096ERH0:
Table of Contents

Advertisement

Electronic Parts

❇ Refer to electronic contorol device drawing & schematic diagram.
The Product doesn't operate at all.
Trouble 1
Check the voltage of power(AC220V/AC240V, 50Hz).
• The voltage of main power.
• The voltage applied to the unit.
• The connecting method of Indoor/Outdoor connecting cable (each color)
• The P.C.B. Ass'y
(Fuse, Noise Filter, Power Module, Bridge Diode, etc.)
The operation check of the Indoor P.C.B. Ass'y
Procedure
1) The input voltage of power mod-
ule.
2) The output voltage of power mod-
ule.
4) IC04D(7805)
5) IC01A(KIA7036)
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Turn off the main power and wait to 10 seconds
Turn on the main power again.
Does "Beeping" sound is made from the indoor unit?
NO
Specification
1) AC230V ± 30V
: Check the rated voltage
2) 12V ± 3V
4) DC5V
5) The voltage of micom pin 19
: DC4.5V↑
- 55 -
Troubleshooting Guide
YES
• Primarily, the operating condi-
tion of Micom is O.K.
• Check CN-DISP1
CN-DISP2 of indoor PCB
Remedy
1) Check the power outlet.
2) Replace
P.C.B Ass'y
4) Replace P.C.B Ass'y
5) Replace P.C.B Ass'y
LGE Internal Use Only