IMPORTANT SAFETY INFORMATION
Continued from page 3
16. Keep room area clear and free from combustible materials,
gasoline and other flammable vapors and liquids.
17. Unvented gas heaters are a supplemental zone heater. They
are not intended to be a primary heating appliance.
18. During manufacturing, fabricating and shipping, various
components of this appliance are treated with certain oils,
films or bonding agents. These chemicals are not harmful
but may produce annoying smoke and smells as they are
burned off during the initial operation of the appliance;
possibly causing headaches or eye or lung irritation. This
is a normal and temporary occurrence.
The initial break-in operation should last two to three
hours with the burner at the highest setting. Provide
maximum ventilation by opening windows or doors to
allow odors to dissipate. Any odors remaining after this
initial break-in period will be slight and will disappear
with continued use.
19. Input ratings are shown in BTU per hour and are for ele-
vations up to 2,000 feet. For elevations above 2,000 feet,
input ratings should be reduced 4 percent for each 1,000
feet above sea level. See the National Fuel Gas Code.
20. The appliance and its appliance main gas valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 psig (3.5 kPa).
21. The appliance must be isolated from the gas supply piping
system by closing its equipment shutoff valve during any
pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig (3.5 kPa).
4
22. Do not use this room heater if any part has been under
water. Immediately call a qualified service technician to
inspect the room heater and to replace any part of the
control system and any gas control which has been under
water.
23. This appliance must not be used with glass doors in the
closed position. This can lead to pilot outages and severe
sooting outside the fireplace.
24. Never burn solid fuels in a fireplace where a unvented
room heater is installed.
25. Always have a fireplace screen in place when the appliance
is in operation and , unless other provisions for combustion
air are provided, the screen shall have an opening(s) for
induction of combustion air.
26. FOR MASSACHUSETTS RESIDENTS ONLY:
This product must be installed by a
licensed plumber of gas fitter when
installed within the Commonwealth of
Massachusetts.
27. Installation of this vented gas log in the Commonwealth
of Massachusetts requires the damper be permanently
removed or welded in the full open position. In addition, a
naturally vented gas log may not be installed in a bedroom
or bathroom in the Commonwealth of Massachusetts.
Flex line installation must not exceed 36".
Failure to keep the primary air openings
of the burners clean may result in
sooting and property damage.
14D9999