Best Configuration
Each system power supply unit plugged into its own UPS/BBU, each of which is powered by separate,
independent circuits. Protection provided for single system power supply unit failure, power outages,
single UPS/BBU failure, and single facility circuitry failure.
UPS VA Recommendations
When deciding on UPS hardware, it is important to choose a solution with the appropriate VA
rating. This rating allows you to calculate the prospective uptime of a server in the event of a power
failure, based on the power draw of the system. For specific advice on choosing a UPS unit, we
recommend that you contact your preferred hardware vendor and provide the power draw
specifications contained in this document.
Heat
The heat output of your SnapStream appliance will vary directly with the number of hard disks that are in
use. The chart below shows approximate heat output by storage capacity.*
Storage
Chassis
Level
Size
3 TB
3U
6 TB
3U
9 TB
3U
12 TB
3U
18 TB
3U
24 TB
3U
27 TB
3U
36 TB
3U
*NOTE: During system startup, power draw and heat output may temporarily reach levels of up to 150%
of the Load figures noted in these tables.
12
Draw
Draw
Consumed
Consumed
@ Idle
@ Load
116 Watts
193 Watts
154 Watts
222 Watts
184 Watts
251 Watts
165 Watts
231 Watts
202 Watts
265 Watts
179 Watts
248 Watts
224 Watts
293 Watts
224 Watts
293 Watts
Thermal
Output
@ Idle
395.79 BTU/h
525.45 BTU/h
629.17 BTU/h
563.66 BTU/h
689.22 BTU/h
609.38 BTU/h
764.29 BTU/h
764.29 BTU/h
Thermal
Output
@ Load
656.81 BTU/h
757.46 BTU/h
856.41 BTU/h
788.17 BTU/h
904.18 BTU/h
846.18 BTU/h
999.72 BTU/h
999.72 BTU/h
Need help?
Do you have a question about the Enterprise TV Server and is the answer not in the manual?
Questions and answers