Area Measurement; Volume Measurement; Continuous Measurement (Tracking) - Bosch PLR 25 Original Instructions Manual

Hide thumbs Also See for PLR 25:
Table of Contents

Advertisement

OBJ_DOKU-27422-001.fm Page 19 Thursday, July 14, 2011 11:09 AM
Push the measuring button 9 once for sighting and
once more to take the measurement.
The measured value is indicated at the bottom in the
display.

Area Measurement

For area measurements, push button 5. The indicator for area measurement ap-
pears in the display
.
Afterwards, measure the length and the width, one after another, in the same
manner as a length measurement. The laser beam remains switched on between
both measurements.
After taking the second measurement, the area/sur-
face is automatically calculated and displayed. The
last individual measured value is indicated at the bot-
tom in the display, while the final result is shown at
the top.

Volume Measurement

For volume measurements, push button 10. The indicator for volume measure-
ment appears in the display
Afterwards, measure the length, width and the height, one after another, in the
same manner as for a length measurement. The laser beam remains switched on
between all three measurements.
After taking the third measurement, the volume is au-
tomatically calculated and displayed. The last individ-
ual measured value is indicated at the bottom in the
display, while the final result is shown at the top.
Continuous Measurement (Tracking) (see figure C)
For continuous measurements, the measuring tool can be moved relative to the
target, whereby the measuring value is updated approx. every 0.5 seconds. In
this manner, as an example, you can move a certain distance away from a wall,
while the actual distance can always be read.
For continuous measurements, push button 12. The indicator for continuous
measurement (tracking) appears in the display
Press the measuring button 9 to initiate the measur-
ing procedure. Move the measuring tool until the re-
quired distance value is indicated at the bottom of the
display.
Pushing the measuring button 9 interrupts the contin-
uous measurement. The current measured value is in-
dicated in the display. Repeated pushing of the measuring button 9 starts the
continuous measuring again.
The continuous measurement automatically switches off after 5 minutes. The
last measured value remains indicated on the display. The continuous measuring
can also be ended by pushing the buttons 6, 5 or 10 which changes the measur-
ing function.
Bosch Power Tools
.
.
2 609 140 620 | (14.7.11)
English | 19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents