Hitachi RAS-18YH6 Service Manual page 57

Room air conditioner
Hide thumbs Also See for RAS-18YH6:
Table of Contents

Advertisement

6-4. Temperature Detection Circuit
O.H. thermistor
DEF. thermistor
Outdoor temperature
thermistor
The Over heat thermistor circuit detects the temperature at the surface of the compressor head, the Defrost.
thermistor circuit detects the defrosting operation temperature.
A thermistor is a negative resistor element which has the characteristics that the higher (lower) the temperature,
the lower (higher) the resistance.
When the compressor is heated, the resistance of the Over heat thermistor becomes low and voltage to a
pin s of microcomputer is increased.
Microcomputer compares the voltage at pin s with the internal set value, if it is exceeded the set value
microcomputer judges that the compressor is overheated and stops operation.
When frost forms on the outdoor heat exchanger, the temperature at the exchanger drops abruptly. Therefore
the resistance of the Defrost. thermistor becomes high and the voltage at pin w of microcomputer drops.
If this voltage becomes lower than the set value stored inside, the microcomputer starts defrosting control.
During defrosting operation the microcomputer transfers the defrosting condition command to the indoor
microcomputer via the circuit interface.
The microcomputer always reads the outdoor temperature via a thermistor (microcomputer pin x ), an
transfers it to the indoor unit, thus controlling the compressor rotation speed according to the value set at the
EEPROM in the indoor unit, and switching the operation status (outdoor fan on/off, etc.) in the dehumidifying
mode.
The following shows the typical values of outdoor temperature in relation to the voltage:
Table 6-2
Outdoor temperature
R303 Voltage
<Reference>
When the thermistor is open, in open status, or is disconnected, microcomputer pins s,w,x are approx.
0V; when the thermistor is shorted, they are approx. 5 V, and LD301 blinks seven times.
However, an error is detected only when the OH thermistor is shorted; in such a case, the blinking mode
is entered 12 minutes after the compressor starts operation.
Main P.W.B.
+5V
HIC
CN8
1
2
20
+5V
CN9
1
2
21
+5V
CN10
1
2
22
Fig. 6-12
( )
-
C
O
1.19
(V
)
R304
C304
R301
0V
0V
R305
C303
R302
0V
0V
R306
C302
R303
0V
0V
10
0
10
20
1.69
2.23
2.75
– 55 –
OH
59
Microcomputer
AX-8V11
63
DEF
Outdoor
64
temperature
30
40
3.22
3.62