Table 1 Mode data file
LABEL NAME
WMAX
WMAX2
WSTD
WBEMAX
CMAX
CMAX2
CSTD
CKYMAX
CJKMAX
CBEMAX
WMIN
CMIN
STARTMC
DWNRATEW
DWNRATEC
SHIFTW
SHIFTC
CLMXTP
YNEOF
TEION
TEIOF
SFTDSW
DFTIM1
DFTIM2
RAS-18YH6
3500 min
–1
–1
3500 min
2950 min
–1
2800 min
–1
–1
3200 min
–1
3200 min
2400 min
–1
–1
2300 min
–1
2300 min
–1
2300 min
2200 min
–1
–1
2200 min
90 Seconds
80%
60%
2.00°C
1.33°C
30.00°C
25.00°C
2.00°C
9.00°C
1.00°C
43 Minutes
60 Minutes
– 24 –
RAS-25YH6
VALUE
4400 min
4400 min
4200 min
3200 min
3200 min
3200 min
2900 min
2700 min
2500 min
2300 min
2200 min
2200 min
90 Seconds
30.00°C
25.00°C
43 Minutes
60 Minutes
–1
–1
–1
–1
–1
–1
–1
–1
–1
–1
–1
–1
80%
60%
2.00°C
1.33°C
2.00°C
9.00°C
1.00°C