Fig. 3-4 Power module circuit (U
is OFF, V
is ON)
+
Since current flows at point B only when U
transistor and V
transistor are ON, the current waveform
at point B becomes intermittent waveform as shown in Fig. 3-3. Since current at point B is approximately
proportional to the input current of the air conditioner, input current is controlled by using DC current
(Id) detection resistor.
<Reference>
If power module is defected, self diagnosis lamps on the MAIN P.W.B. may indicate as shown below:
Table 3-1
LD303
MAIN P.W.B.
LD302
LD301
IPM
SERVICE SWITCH
HIC
Fig. 3-5
– 44 –