DutchWest DW2500X02 Owner's Manual

Epa certified high efficiency wood insert
Hide thumbs Also See for DW2500X02:

Advertisement

Available languages

Available languages

EPA Certified High Efficiency
SAFETY NOTICE
Read this entire manual before you install and use your fireplace insert. If not properly in-
stalled, a house fire may result. To reduce the risk of fire, follow the installation instructions.
Failure to follow instructions may result in property damage, bodily injury or even death. Con-
tact local building, fire officials or authorities having jurisdiction about permits, restrictions
and installation inspection requirements in your area.
This unit is not mobile home approved.
This appliance is manufactured for a 6" (152 mm) Dia.
Do Not Discard This Manual: Retain for Future Use
Wood Insert
Model DW2500X02
Owner's Manual
D
UTCH
4581
DW2500X02 cover
10/08
chimney connection. (Refer to Page 7)
W
EST
30004581 1/09 Rev. 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DW2500X02 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DutchWest DW2500X02

  • Page 1 EPA Certified High Efficiency Wood Insert Model DW2500X02 Owner’s Manual UTCH SAFETY NOTICE Read this entire manual before you install and use your fireplace insert. If not properly in- stalled, a house fire may result. To reduce the risk of fire, follow the installation instructions.
  • Page 2 DW2500X02 Why the correct chimney size is important CAUTION Your appliance operates best using a minimum 6” (152 After reading these instructions, if you have any doubt mm) diameter chimney. The maximum chimney diam- about your ability to complete your installation in a eter must not exceed 10”...
  • Page 3: Specifications

    Under specific conditions this heater has been shown to deliver heat at rates ranging from 9,500 to 58,000 BTU per hour. Model DW2500X02 is listed by OMNI-Test Laboratories of Portland, OR and meets UL 1482 for the US and ULC S 627-00 for Canada.
  • Page 4: Installation

    DW2500X02 Installation Clearance to Combustible Constructions 1. Remove all boxes of firebricks and any packaging Refer to Page 5 for further instructions about floor from inside the appliance. protection. 2. Clean out the masonry fireplace ensuring the ashes FAILURE TO FOLLOW THESE MINIMUM CLEAR- are placed in a metal container.
  • Page 5: Floor Protection

    DW2500X02 ST1031 Figure 3 Install Firebrick Tip - Install Front (*) Fire Bricks First Floor Protection This appliance must be installed in a masonry fireplace ST1031 enclosure built in accordance install firebrick with local building codes. DO 10/08 NOT INSTALL IN A FACTORY...
  • Page 6 DW2500X02 6” (152 mm) Min. Dia. Stainless Steel Flexible Figure 5 Liner Face Plate Assembly NOTES: A stain- less steel adapter is recommended for fastening the stainless steel flexible liner to the collar. Male or crimped end of the adapter must be installed inside the flue collar.
  • Page 7: Blower Installation

    DW2500X02 feet (3 m). Chimney Liner 5. Do not use makeshift compromises during installa- The cross-sec- tion. tional area must not Chimney Con- exceed 85 square 6. Do not remove bricks or mortar from the fireplace. nector into the inches (550 cm EXCEPTION (5) Page 7: first section of...
  • Page 8: Operation

    DW2500X02 Operation Do not use a grate or elevate fire. Build wood fire directly on hearth. When the stove is used for the first Face Plate time the solvents in the paint will smoke off. Wood This heater is designed to burn natural wood only. High- er efficiency and lower emissions generally result when...
  • Page 9: Building A Fire

    DW2500X02 It is normal to see flat spots on painted surfaces of the Inlet Air Control Settings stove. The flat spots on the paint surface indicate the Desired Inlet **Approx. hotter surfaces of the stove, and is caused by the heat...
  • Page 10: Ash Disposal

    DW2500X02 The following steps should be followed for door gasket WARNING: Things to remember in case of chim- replacement: ney fire: 1. Close draft control. 2. Call the fire de- 1. Ensure appliance is not in operation and has thor- partment.
  • Page 11 DW2500X02 kindling, some additional kindling may be needed 5. Why can’t I get the fire lit? to sustain the fire. DO NOT add more paper after Damp or wet wood and poor draft are the main rea- the fire has started.
  • Page 12 DW2500X02 This condition is commonly referred to as down d. Chimney Installation and Maintenance drafting. There are several factors that impact the Avoid using too many elbows or long horizontal amount of air available in the home. Increased runs. If in doubt, contact a chimney expert and/or amounts of insulation vinyl windows, extra caulk- chimney manufacturer for help.
  • Page 13 DW2500X02 MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. DW2500X02 Wood Insert 4581 DW2500x2 parts Item No. Description Qty. Part No. 10/08 Door Casting - Black...
  • Page 14 DW2500X02 DW2500X02 Wood Insert (continued) Item No. Description Qty. Part No. Baffle Assembly S41467 Secondary Air Tube S32711 Cotter Pin S11421 Firebrick 4⁷⁄₁₆” (113 mm) x 9” (229 mm) x 1¹⁄₄” (32 mm) S16040 Firebrick 4⁷⁄₁₆” (113 mm) x 7¹⁄₄” 184 mm) x 1¹⁄₄” (32 mm) S16043 Firebrick 4⁷⁄₁₆”...
  • Page 15: Limited Lifetime Warranty

    • Corrosive driftwood, manufactured logs or other fuels are 1. The new Dutchwest product must be installed and operated at all used other than as outlined in the installation and operating times in accordance with the installation and operation instruc- instructions.
  • Page 16: Guide Du Propriétaire

    Note concernant la sécurité 4581 Lire le manuel en entier avant d’installer et d’utiliser votre poêle inséré. DW2500X02 cover Si le poêle n’est pas installé correctement, votre maison pourrait passer au feu. 10/08 Pour réduire les risques d’incendie, observez les instructions d’installation.
  • Page 17 DW2500X02 Mise En Garde 14.Une fois que le tirage requis est étabil, n’utilisez votre appareil qu’en tenant les portes fermées; ovrez Aprés avoir lu ces instructions, si vous avez des doutes les portes lentement lorsque vous remettez du bois quant à votre capacité de faire toute l’installation d’une dans le foyer.
  • Page 18: Caractéristiques

    DEUSES. Caractéristiques Modéle DW2500X02 non-catalytique. Ce poêle respecte les limits d’emission pour les poêles à bois fixées par l’agence Américaine de protection de l’environnement. Dans des conditions spécifiques, ce poêle dégage entre 9 500 à 58 000 BTU à l’heure.
  • Page 19 DW2500X02 Installation 1. Retirez de l’appareil toute boîte de briques et autres l’arrière de l’appareil) et ci-dessous, pour la sépara- paquets. tion des matériaux combustibles et la protection du plancher. Voir à la page 5 d’autres instructions au 2. Nettoyez le foyer en maçonnerie et assurez-vous sujet de la protection des planchers.
  • Page 20 DW2500X02 Figure 3 Installation de la brique réfractaire Avis - Installer les briques (*) du devant en premier ST1031 install firebrick 10/08 30004581...
  • Page 21 DW2500X02 3. Faire glisser la plaque frontale contre le mur de locales du bâtiment pour les conditions requis dans maçonnerie. Attention : Pour éviter de détériorer la votre region. surface supérieure du poêle, utiliser comme protec- 2. Vous devriez faire inspecter votre cheminée en tion le bulletin d’installation fourni avec ce panneau...
  • Page 22 DW2500X02 cale (inspection des bâtiments). Lors de l’installation aux cheminées, fabriquées en usine, de type rési- en conjonction avec une cheminée de maçonnerie, dentiel et les appareils de chauffage des bâtiments, on doit installer dans la première section de la UL103;...
  • Page 23 DW2500X02 Chemisage de protection Poêle inséré Étiquette Ouvert en métal ST1029 Ferme ST1028 Figure 9 Installée une étiquette sur le foyer ������ Poignée à ressort Assemblage le ventilateur ����� ��� ����� 1. Retirez les vis du poêe inséré; passez le cordon sous le corps et passez-le par la débouchure.
  • Page 24: Utilisation Du Poêle

    DW2500X02 Pendant le mûrissement de la peinture, cette dernière Utilisation du poêle deviendra collante. Une fois qu’elle est mûrie, la peinture restera dure. Il est normal de voir des en- N’utilisez pas de grille dans le poêle pour relever le feu.
  • Page 25 DW2500X02 d’air pour que le bois mieux allumé produise plus de Remplacement d’un joint flammes. bien que vous ayez la règle pratique de (à Aprés un usage intensif, le matériau des joints de la peine ouvert), (à demi ouvert) et (totalement ouvert), porte et de la vitre peut devoir être remplacé...
  • Page 26 DW2500X02 Comment prévenir l’accumulation de créosote Élimination de la cendre 1. Plusieurs fois par jour durant la saison de chauffage, L’appareil est muni d’une tablette sure le devant pour ouvrez le volet d’admission d’air pendant plusieurs faciliter l’enlèvement de la cendre. En usage continu minutes;...
  • Page 27 DW2500X02 2. Quel est le meilleur type de bois qu’on peut IMPORTANT utiliser dans le poêle? Conseils qui valent la peine d’être répétés Vous devriez utiliser du bois dur sec. Évitez d’utiliser du bois vert. En plus de donner un rendement d’à...
  • Page 28 DW2500X02 8. Qu’entend-on par tirage? b. Conditions environnementales Le tirage peut être exprimé comme étant la capacité Les grands arbres, les dépressions, comme une de la cheminée à évacuer les sous-produits de toule vallée, les grands édifices ou structures adjacents combustion normale.
  • Page 29 MHSC se réserve le droit de faire des changements en ce qui concerne la conception, les matériaux, les spécifications et les prix et de discontinuer des couleurs et des produits à tout moment sans préavis. Poêle inséré DW2500X02 4581 DW2500x2 parts...
  • Page 30 DW2500X02 Poêle inséré DW2500X02 (suite) Description Qtée. No. pièce Baffle AssemblyDéflecteur S41467 Tube d’air secondaire S32711 Goupille fendue S11421 Brique réfractaire 113 mm (4⁷⁄₁₆ po) x 229 mm (9 po) x 32 mm (1¹⁄₄ po) S16040 Brique réfractaire 113 mm (4⁷⁄₁₆ po) x 184 mm (7¹⁄₄ po) x 32 mm (1¹⁄₄ po) S16043 Brique réfractaire 113 mm (4⁷⁄₁₆...
  • Page 31 MHSC garantit que les poêles à bois en fonte ou les foyers à bois en pierres 6. Toutes les autres garanties - expresses ou implicites - relatives au de marque Dutchwest sont exemple de tout défaut de fabrication et de ma- produit, à ses compaosantes et accessoires ou à toute obligation ou térel pour une période de trois ans depuis la date de vente, sous réserve...
  • Page 32 MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com...

Table of Contents