This manual describes the installation and operation of the Model DW2500X02 non-
catalytic wood heater. This heater meets US Environmental Protection Agency emis-
sion limits for wood heaters. Under specific conditions this heater has been shown to
4581
deliver heat at rates ranging from 9,500 to 57,800 BTU/hr.
DW2500X02 cover
10/08
SAfEty notICE
Read this entire manual before you install
and use your fireplace insert. If not properly
installed, a house fire may result. to reduce
the risk of fire, follow the installation instruc-
tions. failure to follow instructions may re-
sult in property damage, bodily injury or even
death. Contact local building, fire officials or
authorities having jurisdiction about permits,
restrictions and installation inspection re-
quirements in your area.
this unit is not mobile home approved.
This stove is listed by OMNI-Test Laboratories of Port-
land, Oregon to meet UL1482 for the US and ULC-S628
for Canada.
Do not Discard this Manual: Retain for future Use
D
W
UTCH
EST
EPA Certified High
Efficiency Wood
Insert
Model DW2500X02
owner's Manual
this appliance is manufactured for a 6"
(152 mm) Dia. chimney connection. (Refer
to Page 7)
30004581 5/09 Rev. 3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DW2500X02 and is the answer not in the manual?

Questions and answers

Summary of Contents for DutchWest DW2500X02

  • Page 1 Manual UTCH This manual describes the installation and operation of the Model DW2500X02 non- catalytic wood heater. This heater meets US Environmental Protection Agency emis- sion limits for wood heaters. Under specific conditions this heater has been shown to 4581 deliver heat at rates ranging from 9,500 to 57,800 BTU/hr.
  • Page 2: About Your Appliance

    DW2500X02 Why the correct chimney size is important CAUtIon Your appliance operates best using a minimum 6” (152 After reading these instructions, if you have any doubt mm) diameter chimney. The maximum chimney diam- about your ability to complete your installation in a eter must not exceed 10”...
  • Page 3: Specifications

    Under specific conditions this heater has been shown to deliver heat at rates ranging from 9,500 to 58,000 BTU per hour. Model DW2500X02 is listed by OMNI-Test Laboratories of Portland, OR and meets UL 1482 for the US and ULC S 627-00 for Canada.
  • Page 4: Installation

    DW2500X02 Installation Clearance to Combustible Constructions 1. Remove all boxes of firebricks and any packaging Refer to Page 5 for further instructions about floor from inside the appliance. protection. 2. Clean out the masonry fireplace ensuring the ashes fAILURE to foLLoW tHESE MInIMUM CLEAR- are placed in a metal container.
  • Page 5: Floor Protection

    DW2500X02 ST1031 Figure 3 Install Firebrick Tip - Install Front (*) Fire Bricks First floor Protection This appliance must be installed in a masonry fireplace ST1031 enclosure built in accordance install firebrick with local building codes. Do 10/08 not InStALL In A fACtoRy...
  • Page 6 DW2500X02 6” (152 mm) Min. Dia. Stainless Steel Flexible Figure 5 Liner Face Plate Assembly notES: A stain- less steel adapter is recommended for fastening the stainless steel flexible liner to the collar. Male or crimped end of the adapter must be installed inside the flue collar.
  • Page 7: Blower Installation

    DW2500X02 feet (3 m). Chimney Liner 5. Do not use makeshift compromises during installa- The cross-sec- tion. tional area must not Chimney Con- exceed 85 square 6. Do not remove bricks or mortar from the fireplace. nector into the inches (550 cm...
  • Page 8: Operation

    DW2500X02 operation Do not use a grate or elevate fire. Build wood fire directly on hearth. When the stove is used for the first Face Plate time the solvents in the paint will smoke off. Wood This heater is designed to burn natural wood only. High-...
  • Page 9: Building A Fire

    DW2500X02 It is normal to see flat spots on painted surfaces of the Inlet Air Control Settings stove. The flat spots on the paint surface indicate the Desired Inlet **Approx. hotter surfaces of the stove, and is caused by the heat...
  • Page 10: Ash Disposal

    DW2500X02 The following steps should be followed for door gasket WARnInG: things to remember in case of chim- replacement: ney fire: 1. Close draft control. 2. Call the fire de- 1. Ensure appliance is not in operation and has thor- partment.
  • Page 11 DW2500X02 kindling, some additional kindling may be needed 5. Why can’t I get the fire lit? to sustain the fire. Do not add more paper after Damp or wet wood and poor draft are the main rea- the fire has started.
  • Page 12 DW2500X02 This condition is commonly referred to as down d. Chimney Installation and Maintenance drafting. There are several factors that impact the Avoid using too many elbows or long horizontal amount of air available in the home. Increased runs. If in doubt, contact a chimney expert and/or amounts of insulation vinyl windows, extra caulk- chimney manufacturer for help.
  • Page 13 DW2500X02 MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. DW2500X02 Wood Insert 4581 DW2500x2 parts Item No. Description Qty. Part No. 10/08 Door Casting - Black...
  • Page 14 DW2500X02 DW2500X02 Wood Insert (continued) Item No. Description Qty. Part No. Baffle Assembly S41467 Secondary Air Tube S32711 Cotter Pin S11421 Firebrick 4M\zn” (113 mm) x 9” (229 mm) x 1Z\v” (32 mm) S16040 Firebrick 4M\zn” (113 mm) x 7Z\v” 184 mm) x 1Z\v” (32 mm) S16043 Firebrick 4M\zn”...
  • Page 15: Limited Lifetime Warranty

    • Corrosive driftwood, manufactured logs or other fuels are 1. The new Dutchwest product must be installed and operated at all used other than as outlined in the installation and operating times in accordance with the installation and operation instruc- instructions.
  • Page 16 4581 Lire le manuel en entier avant d’installer et d’utiliser votre po le ins r . DW2500X02 cover Si le po le n’est pas install correctement, votre maison pourrait passer au feu. 10/08 Pour r duire les risques d’incendie, observez les instructions d’installation.
  • Page 17 DW2500X02 Mise En Garde 14.Une fois que le tirage requis est tabil, n’utilisez votre appareil qu’en tenant les portes ferm es; ovrez Apr s avoir lu ces instructions, si vous avez des doutes les portes lentement lorsque vous remettez du bois quant votre capacit de faire toute l’installation d’une...
  • Page 18 DEUSES. Caract ristiques Mod le DW2500X02 non-catalytique. Ce po le respecte les limits d’emission pour les po les bois fix es par l’agence Am ricaine de protection de l’environnement. Dans des conditions sp cifiques, ce po le d gage entre 9 500 58 000 BTU l’heure.
  • Page 19 DW2500X02 Installation 1. Retirez de l’appareil toute bo te de briques et autres l’arri re de l’appareil) et ci-dessous, pour la s para- paquets. tion des mat riaux combustibles et la protection du plancher. Voir la page 5 d’autres instructions au 2.
  • Page 20 DW2500X02 ST1031 Figure 3 Installation de la brique r fractaire Avis - Installer les briques (*) du devant en premier Protecteur de plancher Cet appareil doit tre install ST1031 dans une enceinte de foyer en install firebrick ma onnerie construite conform -...
  • Page 21 DW2500X02 3. Faire glisser la plaque frontale contre le mur de locales du b timent pour les conditions requis dans ma onnerie. Attention : Pour viter de d t riorer la votre region. surface sup rieure du po le, utiliser comme protec- 2.
  • Page 22 DW2500X02 cale (inspection des b timents). Lors de l’installation aux chemin es, fabriqu es en usine, de type r si- en conjonction avec une chemin e de ma onnerie, dentiel et les appareils de chauffage des b timents, on doit installer dans la premi re section de la UL103;...
  • Page 23 DW2500X02 Chemisage de protection Po le ins r tiquette Ouvert en m tal ST1029 Ferme ST1028 Figure 9 Install e une tiquette sur le foyer Poign e ressort Assemblage le ventilateur 1. Retirez les vis du po e ins r ; passez le cordon sous le corps et passez-le par la d bouchure.
  • Page 24 DW2500X02 Pendant le m rissement de la peinture, cette derni re Utilisation du po le deviendra collante. Une fois qu’elle est m rie, la peinture restera dure. Il est normal de voir des en- N’utilisez pas de grille dans le po le pour relever le feu.
  • Page 25 DW2500X02 d’air pour que le bois mieux allum produise plus de Remplacement d’un joint flammes. bien que vous ayez la r gle pratique de ( Apr s un usage intensif, le mat riau des joints de la peine ouvert), ( demi ouvert) et (totalement ouvert), porte et de la vitre peut devoir tre remplac s’il a perdu...
  • Page 26 DW2500X02 Comment pr venir l’accumulation de cr osote limination de la cendre 1. Plusieurs fois par jour durant la saison de chauffage, L’appareil est muni d’une tablette sure le devant pour ouvrez le volet d’admission d’air pendant plusieurs faciliter l’enl vement de la cendre. En usage continu minutes;...
  • Page 27 DW2500X02 2. Quel est le meilleur type de bois qu’on peut IMPoRtAnt utiliser dans le po le? Conseils qui valent la peine d’ tre r p t s Vous devriez utiliser du bois dur sec. vitez d’utiliser du bois vert. En plus de donner un rendement d’...
  • Page 28 DW2500X02 8. Qu’entend-on par tirage? b. Conditions environnementales Le tirage peut tre exprim comme tant la capacit Les grands arbres, les d pressions, comme une de la chemin e vacuer les sous-produits de toule vall e, les grands difices ou structures adjacents combustion normale.
  • Page 29 MHSC se r serve le droit de faire des changements en ce qui concerne la conception, les mat riaux, les sp cifications et les prix et de discontinuer des couleurs et des produits tout moment sans pr avis. Po le ins r DW2500X02 4581 DW2500x2 parts...
  • Page 30 DW2500X02 Po le ins r DW2500X02 (suite) Description Qt e. no. pi ce Baffle AssemblyD flecteur S41467 Tube d’air secondaire S32711 Goupille fendue S11421 Brique r fractaire 113 mm (4M\zn po) x 229 mm (9 po) x 32 mm (1Z\v po)
  • Page 31 6. Toutes les autres garanties - expresses ou implicites - relatives au de marque Dutchwest sont exemple de tout d faut de fabrication et de ma- produit, ses compaosantes et accessoires ou...
  • Page 32 MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com...