1
INSTALL THE COOKTOP
A. Remove the screws on the sides of the cooktop
burner box. Use those screws to attach the side
mounting brackets.
B. Insert the cooktop centered into the cutout
opening. Make sure the front edge of the
countertop is parallel to the cooktop.
Check clearances at the front, back and sides.
Cooktop
Secure the hold-down bracket to the cabinet
sides with screws.
2
INSTALL PRESSURE REGULATOR
WARNING:
connectors. The use of old flexible connectors can
cause gas leaks and personal injury. Always use
new flexible connectors when installing a gas
appliance.
To reduce the possibility of gas leaks, apply teflon
tape or a thread compound approved for use with
LP or Natural gases to all threaded connections.
A. Screw the regulator onto the burner box
bottom pipe connection. Make sure the top of
the regulator is facing toward the cabinet front,
and the arrow on the back of the regulator
points to the cooktop.
Pressure
regulator
Shut-off
valve
B. Complete the connection between the regulator
and the shut-off valve.

Installation Instructions

Never reuse old flexible
To cooktop
Rear view
of
regulator
(note
direction
of arrow)
Electrical outlet 12"
below countertop
2
INSTALL PRESSURE REGULATOR
(cont.)
C. Before testing for leaks, make sure all burner
knobs are in the OFF position.
After connecting the cooktop to gas, check
system for leaks with a manometer. If a manometer
is not available, turn the gas supply on to the
cooktop and use a liquid leak detector at all
joints and connections to check for leaks.
Tighten all connections if necessary to prevent gas
leakage in the cooktop or supply line.
WARNING:
check for leaks.
Disconnect the cooktop and its individual shut-off
valve from the gas supply piping system during any
pressure testing of that system at test pressures
greater than 1/2 psig (3.5 kPa).
Isolate the cooktop from the gas supply piping
system by closing its individual shut-off valve during
any pressure testing of the gas supply system at
test pressures equal to or less than 1/2 psig (3.5 kPa
3
CONNECT ELECTRICAL
• Check to be sure the receptacle is properly
grounded.
• Plug in the power cord.
9