21" (533mm) Deep with grille Weight 125 lb (57kg) JBL continually strives to update and improve existing products, as well as create new ones. The specifications and details in this and related JBL publications are therefore subject to change without notice.
1500 Array Subwoofer 1500 Array Powered Sub/ Plate Amp LINE VOLTAGE Yes/No Hi/Lo Line Nom. Unit Notes US 120VAC/60Hz 108-132 Vrms Normal Operation EU 230VAC/50-60Hz 207-264 Vrms Normal operation, MOMS required Asia 100VAC/50Hz 90-110 Vrms Normal operation, MOMS required QA Test...
Page 5
1500 Array Subwoofer QA Test Parameter Specification Unit Limits Conditions Notes Transients/Pops ATO Transient mV-peak @ Speaker Output Turn-on Transient mV-peak 1V-pk-pk @ Speaker Output AC Line cycled from OFF to ON Turn-off Transient mV-peak 1V-pk-pk @ Speaker Output AC Line cycled from ON to OFF...
® receiver/processor with a low-frequency- effects (LFE) output, set LFE/LP switch to LFE. If you prefer to use the crossover built into the 1500 Array, set the LFE/LP Switch ¶ to LP. SUBWOOFER OR LFE OUTPUT The 1500 Array includes a line output.
1500 Array Subwoofer 1500 ARRAY OPERATION Power On plug connected to a “live” If your main speakers can receptacle? Has the Power comfortably reproduce some Plug your subwoofer’s AC cord Switch ª been pressed to low-frequency sounds, set this into a wall outlet. Do not use the “on”...
1500 Array Subwoofer BASIC TROUBLESHOOTING If there is low (or no) bass output • Make sure the connections to the left and right “Speaker Inputs” have the correct polarity (+ and –). • Make sure the subwoofer is plugged into an active electrical outlet.
1500 Array Subwoofer 1500 ARRAY SUB EXPLODED VIEW X RAY VIEW FOR ILLUSTRATIVE PURPOSES ONLY DAMPING MATERIAL NOT SHOWN 1500 ARRAY MECHANICAL PARTS LIST Item # Description Part Number CABINET ASSEMBLY-1500 ARRAY Not for Sale 15" WOOFER-W1500H 353721-001 AMPLIFIER ASSEMBLY,120V-ARRAY...
1500 Array Subwoofer 1500 Array TEST PROCEDURE Equipment needed: • Function/signal generator/sweep generator • Multimeter • RCA cable General Unit Function (UUT = Unit Under Test) Switch/Controls: GAIN control full Counterclockwise (Min) CROSSOVER (Hz) Full Clockwise (140) PHASE switch - either position LFE/LP –...
Page 14
1500 Array Subwoofer Part number Qty Description Reference Designator FUSE PCB 043-324300-000ZR GR INDUCTOR 324uH YT-10778 025-006000-000ZR GR Thermister P/N:CL-60 POWER PCB Capacitors 032-100484-200ZS GS END Mylar cap. 1uF/250V K P:15 C410,418,427 034-680794-200ZR GR Elec. Cap. (LP) 85℃ 6800uF/80V M (R)3050 P:10...