  • Page 1 – 1 –...
  • Page 2: Safety Precaution

    SAFETY PRECAUTION Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit. Pay special attention to signs of “ Warning” and “ Caution”. The “Warning” section contains matters which, if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result in serious consequences if not observed properly.
  • Page 3 PRECAUTIONS DURING OPERATION The product shall be operated under the manufacturer specification and not for any other intended use. Do not attempt to operate the unit with wet hands, this could cause fatal accident. When operating the unit with burning equipments, regularly ventilate the room to avoid oxygen insufficiency.
  • Page 4: Names And Functions Of Each Part

    AIR INLET (BACK, LEFT SIDE) AIR OUTLET DRAIN PIPE RAC-T13CE Condensed water drain to outside. CONNECTING CORD AIR INLET (BACK, LEFT SIDE) AIR OUTLET MODEL NAME AND DIMENSIONS MODEL WIDTH (mm) HEIGHT (mm) DEPTH (mm) RAS-T10CE / T13CE RAC-T10CE RAC-T13CE – 4 –...
  • Page 5 INDOOR UNIT INDICATORS OPERATION LAMP This lamp lights during operation. HITACHI TIMER LAMP This lamp lights when the timer is working. FILTER LAMP When the device is operated for a total of about 200 hours, the FILTER lamp lights to indicate that it is time to clean the filter.
  • Page 6: Names And Functions Of Remote Control Unit

    NAMES AND FUNCTIONS OF REMOTE CONTROL UNIT REMOTE CONTROLLER This controls the operation of the indoor unit. The range of control is about 7 meters. If indoor lighting is controlled electronically, the range of control may be shorter. This unit can be fixed on a wall using the fixture provided. Before fixing it, make sure the indoor unit can be controlled from the remote controller.
  • Page 7: Automatic Operation

    AUTOMATIC OPERATION The device will automatically determine the mode of operation COOL, or Dehumidify, depending on the initial room temperature. The selected mode of operation will not change when the room temperature varies. Press the FUNCTION selector so that the display indicates (AUTO) mode of operation.
  • Page 8: Cooling Operation

    COOLING OPERATION Use the device for cooling when the outdoor temperature is 21-43°C. If humidity is very high (over 80°C) indoors, some dew may form on the air outlet grille of the indoor unit. Press the FUNCTION selector so that the display indicates (COOL).
  • Page 9: Dehumidifying Operation

    DEHUMIDIFYING OPERATION Use the device for dehumidifying when the room temperature is over 16°C. When it is under 15°C, the dehumidifying function will not work. Press the FUNCTION selector so that the display indicates (DEHUMIDIFY). ˚ The FAN SPEED is set at LOW automatically. The FAN SPEED button does not work.
  • Page 10: Fan Operation

    FAN OPERATION You can use the device simply as an air circulator. Use this function to dry the interior of the indoor unit at the end of summer. Press the FUNCTION selector so that the display indicates (FAN). Press the (FAN SPEED) button.
  • Page 11: Super Cooling

    SUPER COOLING Press the button. ˚ Operation start with a signal received sound “beep”. Unit will be forced operate in (COOL) with SUPER HI fan speed for 20 minutes. Indicator appear during this period while temperature and fan speed setting display remain unchanged.
  • Page 12: Super Silent

    SUPER SILENT Press the button. ˚ Operation start with a signal received sound “beep”. Unit will be forced operate in any operation mode as before with SUPER SILENT fan speed. The indication of operation mode, temperature setting, fan speed and timer value on remote controller will remain no change.
  • Page 13: Adjusting The Air Deflector

    ADJUSTING THE AIR DEFLECTOR Adjustment of the conditioned air in the upward and downward directions. According to “Dehumidifying” or “Cooling” operation, the horizontal air deflector is automatically set to the proper RESET angle suitable for each operation. The deflector can be swing up and down and also set to the desired angle using the “...
  • Page 14: How To Set The Timer

    HOW TO SET THE TIMER Time, Day, Month Set the current month and TIME, DAY, day with the TIMER control After you change the MONTH button. batteries; (current time, day, month) OFF TIMER RESET ON TIMER OFF-Timer Press the (OFF-TIMER) button.
  • Page 15 Set the current time with the Press the (TIME) button again. Press the TIMER control button. The time indication starts lighting (TIME) button. instead of flashing. The time indication will disappear automatically in 10 seconds. To check the current time setting, press the (TIME) button twice.
  • Page 16: How To Set The Sleep Timer

    HOW TO SET THE SLEEP TIMER Set the current time at first if it is not set before (see the pages for setting the current time). Press the (SLEEP) button, and the display changes as shown below. Mode Indication 1 hour 2 hours 3 hours 7 hours...
  • Page 17: Explanation Of The Sleep Timer

    Explanation of the sleep timer The device will control the FAN SPEED and room temperature automatically so as to be quiet and good for people’s health. You can set the sleep timer to turn off after 1, 2, 3 or 7 hours. The FAN SPEED and room temperature will be controlled as shown below.
  • Page 18: Suitable Room Temperature

    THE IDEAL WAYS OF OPERATION Suitable Room Temperature Install curtain or blinds Warning It is possible to Freezing temperature reduce heat entering the is bad for health and a waste of electric power. room through windows. Ventilation Effective Usage Of Timer At night, please use the “sleep timer operation Caution mode”, together with your wake up time in the...
  • Page 19 FOR USER’S INFORMATION The Air Conditioner And The Heat Source In The Room Caution If the amount of heat in the room is above the cooling capability of the air conditioner (for example: more people entering the room, using heating equipments and etc.), the preset room temperature cannot be achieved.
  • Page 20: Attaching The Air Cleansing Filters

    ATTACHING THE AIR CLEANSING FILTERS CAUTION Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning, stop operation and switch off the power supply. Open the front panel. Pull up the front panel by holding it at both sides with both hands.
  • Page 21: Maintenance

    MAINTENANCE CAUTION Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning, stop operation and switch off the power supply. AIR FILTER Clean the air filter, as it removes dust inside the room. In case the air filter is full of dust, the air flow will decrease and the cooling capacity will be reduced.
  • Page 22 CLEANING OF FRONT PANEL Wipe it with a soft dry cloth. When it is excessively dirty, wipe with a soft cloth soaked in lukewarm water or neutral detergent. Then wipe thoroughly with a soft dry cloth. Wipe the remote controller thoroughly with a soft dry cloth.
  • Page 23: Regular Inspection

    CAUTION Please use earth line. Do not place the earth line near water or gas pipes, lightning-conductor, or the earth line of telephone. Improper installation of earth line may cause electric shock. A circuit breaker should be installed depending on the mounting site of the unit. Without a circuit breaker, the danger of electric shock exists.
  • Page 24 AFTER SALE SERVICE AND WARRANTY WHEN ASKING FOR SERVICE, CHECK THE FOLLOWING POINTS. CONDITION CHECK THE FOLLOWING POINTS Is the fuse all right? Is the voltage extremely high or low? When it does not operate Is the circuit breaker “ON”? Is the air filter blocked with dust? Does sunlight fall directly on the outdoor unit? Is the air flow of the outdoor unit obstructed?
  • Page 25 This product conforms with the protection requirements of council directives 89/336/EEC relating to electromagnetic compatibility and 73/23/EEC relating to electrical equipment designed for use within certain voltage limits. Please note: On switching on the equipment, particularly when the room light is dimmed, a slight brightness fluctuation may occur.
  • Page 26 MEMO ................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................– 26 –...