GROUNDING THE GENERATOR

Grounding the generator helps prevent electric shock from a ground fault condition. To ground the generator you will
need a ground wire and grounding stake. These are not supplied with the generator. The ground wire should be a
3.5mm
2
, stranded-copper wire. The grounding point should be copper or brass.
1. Locate the ground terminal side of the generator control panel.
2. Attach a ground wire to the ground terminal.
3. Drive the grounding point into the ground.
4. Attach the ground wire to the grounding point.
WARNING: Use only grounded extension cords. Use only three wire or double-insulated power tools.
WARNING: Do not use metal pipe that is being used to carry combustible materials or gasses for the
grounding point.

REPLACEMENT PARTS

When servicing use only identical replacement parts.
Repairs should be conducted only by a HITACHI authorized service center.
USE PROPER ELECTRICAL CORD
WARNING: Avoid electrical shock hazard. Never use this generator with a damaged or frayed
electrical cord or extension cord.
Inspect all electrical cords regularly. Never use in or near water or in any environment
where electric shock is possible.