IMPORTANT
If the cooker is suitable for use with Natural gas and must be converted for use with
ULPG, before connecting to gas main remove the appliance gas regulator and replace
with test point adaptor (see figs. 6a - 6b)
If the cooker is suitable for use with ULPG and must be converted for use with Natural
gas, before connecting to the gas main remove the appliance test point adaptor and
replace with gas regulator (see figs. 6a - 6b).
NOTE:
Gas regulator and test point adaptor are supplied with the appliance (packed with conver-
sion kit)
The burners are designed so that regulation of primary air is not required.
MINIMUM BURNER SETTING ADJUSTMENT
Check whether the flame spreads to all burner ports when the burner is lit with the gas
tap set to the minimum position. If some ports do not light, increase the minimum gas rate
setting.
Check whether the burner remains lit even when the gas tap is turned quickly from the
maximum to the minimum position. If the burner does not remain lit, increase the minimum
gas rate setting.
The procedure for adjusting the minimum gas rate setting is described below.
Turn on the burner.
Turn the tap to the MINIMUM position.
Take off the knob.
With a small flat screwdriver turn the screw "F" (fig. 11) to the correct regulation.
Normally for ULPG, the regulation screw is tightened up.