Hitachi ED-X10 Service Manual page 13

Multimedia lcd projector
Hide thumbs Also See for ED-X10:
Table of Contents

Advertisement

Power can not be turned on
Are
voltage
supplied at pins (6)
and (8) of E800 on the PWB
assembly MAIN in
standby mode?
(6): +6.0V
(8): +4.0V
YES
(10): GND
Are
voltage supplied
at pins (1) and (4) of E800
on the PWB assembly
MAIN in standby
mode?
(1): +15V
(3): GND(for +15V)
YES
(4): +17V
(10): GND(for +17V)
Does LAMP
(D303) or TEMP (D302)
indicator light or
blink?
NO
PWB assembly MAIN
ED-X10/ED-X12(CC9XM2)
*: Be sure to unplug the power cord before measuring resistance.
Measure
resistance* between pins
NO
(6) and (10), and between
pins (8) and (10) of
E800.
Disconnect TSW
from power unit circuit, and
measure resistance of
TSW.
Power unit (circuit)
Mea-
sure resistance*
NO
between pins (1) and (3),
and between pins (4) and
(10) of E800.
Power unit (circuit)
YES
Go to the next page
13
Open
Open
Short
Fuse on the power unit
(circuit)
Open
PWB assembly MAIN
Power unit (circuit)
Termal switch (TSW)
PWB assembly MAIN
Power unit (circuit)