Gas Dryer
RECONNECTING GAS
3
Listed connector ANSIZ21.24 / CSA 6.10
FLARE
NPT
NEW METAL
FLEXIBLE GAS LINE
CONNECTOR
ADAPTER
ELBOW
Note: The connector and fittings are designed for use only on the
original installation and are not to be reused for another appliance or
at another location. Keep flare end of adapter free of grease, oil and
thread sealant.
Caution: Use adapters as shown. Connector nuts must not be
connected directly to pipe threads.
APPLY PIPE COMPOUND
TO THE ADAPTER AND
DRYER GAS INLET.
ADAPTER
0.3 cm (1/8") NPT
PIPE PLUG FOR
CHECKING GAS
INLET PRESSURE
SHUT-OFF
VALVE
0.9 cm
(3/8") NPT
PIPE SIZE
AT LEAST
1.2 cm (1/2")
APPLY PIPE COMPOUND
TO ALL MALE THREADS.
Tighten all connections using two adjustable wrenches.
Do not overtorque gas connections!
LEAK TEST
4
WARNING -
NEVER USE AN OPEN
FLAME TO TEST FOR GAS LEAKS.
OPEN GAS
VALVE.
Check all connections for leaks with soapy solution or equivalent.
Apply soap solution. Leak test solution must not contain ammonia
which could cause damage to the brass fittings. If leaks are
found, close valve, retighten the joint, and repeat the soap test .