Obh529A; Service Functions - Mitsubishi Electric MSC-GE20VB Service Manual

Split-type air conditioners
Hide thumbs Also See for MSC-GE20VB:
Table of Contents

Advertisement

8

SERVICE FUNCTIONS

MSC-GE20VB
MS-GE50VB
MSC-GE25VB
MSH-GE50VB
MSC-GE35VB
8-1. TIMER SHORT MODE
For service, set time can be shortened by short circuit of JPG and JPS on the electronic control P.C. board. (Refer to 10-6.)
The time will be shortened as follows.
Set time: 1 minute
1-second
Set time: 3 minute
3-second (It takes 3 minutes for the compressor to start operation. However, the starting time is short-
8-2. P.C. BOARD MODIFICATION FOR INDIVIDUAL OPERATION
A maximum of 4 indoor units with wireless remote controllers can be used in a room.
In this case, to operate each indoor unit individually by each remote controller, P.C. boards of remote controller must be
modified according to the number of the indoor unit.
How to modify the remote controller P.C. board
Remove batteries before modification.
The board has a print as shown below:
NOTE: For modification, take out the batteries and press the OPERATE/STOP (ON/OFF) button 2 or 3 times at first.
After modification, put back the batteries then press the RESET button.
The P.C. board has the print "J1" and "J2". Solder "J1" and "J2" according to the number of indoor unit as shown in Table 1.
After modification, press the RESET button.
Table 1
No. 1 unit
No. 2 unit
No. 3 unit
No. 4 unit
How to set the remote controller exclusively for particular indoor unit
After you turn the breaker ON, the first remote controller that sends the signal to the indoor unit will be regarded as the
remote controller for the indoor unit.
The indoor unit will only accept the signal from the remote controller that has been assigned to the indoor unit once they are
set. The setting will be cancelled if the breaker has turned off, or the power supply has shut down.
Please conduct the above setting once again after the power has restored.
8-3. REMOTE CONTROLLER (How to set the type) MSC-GE
This remote controller setting needs to be switched according to the type of air conditioner (COOL & HEAT or COOL
ONLY).
If the setting is incorrect, the air conditioner does not operate normally. Therefore, check if the setting corresponds to the
type of-air conditioner. If not, correct the setting as shown below.

OBH529A

ened by short circuit of JPG and JPS.)
J1
1 unit operation
No modification
Slide switch
J2
2 units operation
Same as at left
Solder J1
Type
COOL & HEAT
The position
of the slide
switch
11
3 units operation
Same as at left
Same as at left
Solder J2
Solder both J1 and J2
COOL ONLY
4 units operation
Same as at left
Same as at left
Same as at left

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msc-ge25vbMsc-ge35vbMs-ge50vbMsh-ge50vb