PROCEDURE 7
This procedure includes the following:

Installing CLD Front Rigging Release Handle

F
R
After ANY adjustments, repair or service and BE-
O
FORE use, make sure all attaching hardware is
N
tightened securely - otherwise injury or damage
T
may result.
R
INSTALLING CLD FRONT RIGGING
I
RELEASE HANDLE (FIGURE 1)
G
1. Remove the two (2) pan head screws, hex nut, riv
G
nut, bushing and spring from the EXISTING front
I
rigging release handle and retain for later use.
N
2. Position the bushing between the two (2) mounting
G
holes near the tab on the CLD release handle.
Existing Release
Handle
Bushing
Front Rigging
WARNING
EXISTING
Pan
Head
Screws
Hex
Nut
Riv Nut
Spring
FIGURE 1 - INSTALLING CLD FRONT RIGGING RELEASE HANDLE
3. Secure the bushing to the CLD release handle with
a pan head screw and hex nut. Tighten securely.
4. Position mounting hole "A" UNDER mounting hole
"B".
5. Position the hole in the spring UNDER mounting hole
"A" in the orientation shown in FIGURE 1.
NOTE: The bent portion of the spring should hook over
the mounting plate as indicated in FIGURE 1 and the
straight end of the spring should rest inside the CLD re-
lease handle and point away from the tab.
6. Secure the spring and CLD release handle to the
mounting plate with the remaining pan head screw
and riv nut. Tighten securely.
CLD
CLD Release
Handle
Hex Nut
Bushing
Bent Portion
Mounting
of Spring
Hole "A"
Mounting
Plate
HOOK
SPRING HERE
Front
Rigging
22
FRONT RIGGING
Mounting Hole "B"
Pan
Head
Screws
Tab
Straight
Portion
of Spring
Spring
Riv Nut

Advertisement