Warning: This Gas Stove Guard is to be used with Natural Gas Cooking Stoves. It is not designated for use
with Propane cooking Stoves or Space Heaters!
STOVE GUARD is an electronic safety device for use with Natural Gas Stoves. It turns the gas stove OFF when you
forget by using the advanced technology found in security monitoring devices and a specially programmed micro-
controller.
STOVE GUARD controls the stove's gas supply system to help prevent food and pots from burning, as well as
reducing the risk of fire caused by unattended cooking.
STOVE GUARD is preset at the factory at the highest fire safety setting of one minute.
This is the recommended setting for use by anyone with Alzheimer's or similar medical conditions.
  When properly installed, adjusted, and set in AUTO mode, STOVE GUARD will automatically shut the gas
stove off if no one is present in the monitored cooking area (about 10 ft.) for a preset period of time.
  STOVE GUARD can also be used in a TIMER mode to set a maximum cooking time, after which the stove
will be automatically be turned OFF.
 
DO NOT INSTALL
Directly above a heat source or where hot/cold air or steam will blow onto it.
o
On or above a microwave or toaster oven.
o
Directly on or above the gas stove.
o
  Do not allow grease to build up on the motion sensor window. This will reduce STOVE GUARD's sensing
range and possibly turn the stove off even when someone is in front of the gas stove.
  Clean the outer surface of the EMU with a clean, damp cloth only. Do not use soaps or cleaning liquids.
STOVE GUARD must be tested with the Individual who requires this device and adjusted to their personal needs, as
well as adjusted to the home environment of use to ensure proper functioning. Additional fire safety devices; such as
smoke detectors & fire extinguishers must also be used to ensure complete cooking fire safety.
NATURAL GAS STOVE GUARD 2010
Revised June 15, 2011
IMPORTANT TECHNICAL SAFEGUARDS
the EMU (Electronic Monitoring Unit):
IMPORTANT PERSONAL SAFEGUARDS
INSTALLATION & OPERATING MANUAL
Page 1 of 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2010 and is the answer not in the manual?

Questions and answers

Summary of Contents for Stove Guard 2010

  • Page 1 (about 10 ft.) for a preset period of time.   STOVE GUARD can also be used in a TIMER mode to set a maximum cooking time, after which the stove will be automatically be turned OFF.
  • Page 2 GAS VALVE The gas valve is a device that controls gas supply to the gas stove. EMU - ELECTRONIC MONITORING UNIT The control device of Natural Gas Stove Guard. AUTO INDICATOR TIME TIMER 1.
  • Page 3 12. Manually turn off the stove. Press the ON button. Gas supply to stove is established, and the gas stove is ready for use with Stove Guard’s safety features. 13. If user’s personal needs are different from the factory default settings, adjust settings of Stove Guard. Refer to the HOW TO ADJUST THE STOVE GUARD part of manual.
  • Page 4 Display shows number of minutes left before Stove Guard turns off the stove. Once the preset time is over, the Stove Guard will turn the stove off. The movement detection does not work in the TIMER mode.
  • Page 5 TIMER button (4) Turns Stove Guard in TIMER mode and resets time to 01 minute. User has to hold the TIMER button for more than 3 seconds. This delay is a safety feature – avoids accidental activation of timer mode.
  • Page 6   To RAISE the detection field when the EMU cannot be located higher, slowly turn the screw to the LEFT. 2. STOVE GUARD is not detecting the movements of the user because its location is set very high up; the user is very short, or seated in a wheelchair.

This manual is also suitable for:

Guard 2010

Table of Contents