Kenwood TK-280 Service Manual page 42

Hide thumbs Also See for TK-280:
Table of Contents

Advertisement

TK-280
[Panel Tuning Mode except when Panel TEST Mode is specified.]
Item
Condition
12.LTR
1) Adj item [FLTR]
Deviation
Adjust [∗∗∗]
Adjust
LPF:3kHz
HPF:OFF
[Wide]
2) Adj item
[L FLTR] ➞ [C FLTR] ➞ [H FLTR]
Adjust [∗∗∗]
PTT:ON
[Narrow]
3) Adj item [n FLTR]
Adjust [∗∗∗]
PTT:ON
13.DTMF
1) Adj item [DTMF]
Deviation
Adjust [∗∗∗]
Adjust
LPF:15kHz
[Wide]
HPF:OFF
PTT:ON
[Narrow]
2) Adj item [n DTMF]
Adjust [∗∗∗]
PTT:ON
14.MSK
1) Adj item [FMSK]
Deviation
Adjust [∗∗∗]
Adjust
LPF:15kHz
[Wide]
HPF:OFF
PTT:ON
[Narrow]
2) Adj item [n FMSK]
Adjust [∗∗∗]
PTT:ON
15.TONE
1) Adj item [TONE]
Deviation
Adjust [∗∗∗]
Adjust
LPF:15kHz
[Wide]
HPF:OFF
PTT:ON
[Narrow]
2) Adj item [n TONE]
Adjust [∗∗∗]
PTT:ON
16.BATT
1) Adj item [BATT]
Detection
Adjust [∗∗∗]
Writing
PTT:ON
17.BATT
[Panel Test Mode]
Detection
1) CH-Sig:1-1
Check
BATT terminal voltage:6.5V
PTT:ON
2) BATT terminal voltage:5.7V
PTT:ON
42
ADJUSTMENT
Measurement
Test equipment
Unit
Terminal
Power meter
Panel
ANT
Dev meter
universal
Oscilloscope
connector
AG
AF VTVM
Power meter
Panel
ANT
DVM
BATT
terminal
Adjustment
Unit
Parts
Method
Panel
Encoder
1.0kHz
knob
0.75kHz
Wide:2.5kHz ±0.1kHz
Narrow:1.25kHz
Panel
Encoder
After pressing BATT terminal
knob
the PTT switch, voltage:6.2V
confirm that
one predeter-
mined numeric
in the range 1
to 256 appears
and then press
[B] key. That
numeric will be
stored in memory.
Check
Specifications/
Remark
±0.1kHz
±50Hz
No blinking of LED
Blinking of LED

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents