Servicing Information; Distinction Of Lead Free (Pbf) Printed Circuit Board; Indoor Electronic Controllers Removal Procedures - Panasonic CS-MC12DKV Service Manual

Hide thumbs Also See for CS-MC12DKV:
Table of Contents

Advertisement

CS-MC12DKV CU-2C24DKV

12 Servicing Information

12.1. Distinction of Lead Free (PbF) Printed Circuit Board

Printed circuit boards (manufactured) using lead free solder will have a PbF stamp on the Printed Circuit board.
CAUTION
• Pb free solder has a higher melting point than standard solder; typically the melting point is 50 - 70°F (30 - 40°C) higher.
Please use a high temperature solder iron and set it to 700 ± 20°F (370 ± 10°C).
• Pb free solder will tend to splash when heated too high (about 1100° F/600°C).
• If you must use Pb solder, please completely remove all of the Pb free solder on the pin or solder area before applying Pb
solder. If this is not pratical, be sure to heat the Pb free solder until it melts, before applying Pb solder.

12.2. Indoor Electronic Controllers Removal Procedures

• Electronic Controller and Display Complete unit can be
seen by following the below removal procedures
− Remove the 2 caps and 2 screws at the bottom of the
Front Grille. (Fig. 1)
− Remove the Front Grille Complete. (Fig. 2)
Fig. 1
Fig. 2
− Release the taps on top and on the right side of metal
plate cover. (Fig. 3)
− Then remove the metal plate cover. (Fig. 3)
− Remove the indicator complete screw, and then remove
the indicator complete. (Fig. 3)
50
Fig. 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-2c24dkv

Table of Contents