Drying Mode; Heating Mode - Toyotomi Kuro MTN A228DV Service Manual

Dc inverter split wall-mounted type air conditioner
Table of Contents

Advertisement

2) The machine will quit from the rating capacity test mode if running for 5 hours or changing fan
speed or
setting temperature.
9.5.5 Turbo function(press the "TURBO" button on remote controller)
1) Elevate current frequency to a higher grade.
2) Indoor fan turns to turbo speed.
3) After running for 30 minutes the machine will turn back to previous setting mode.
9.5.6
1) In cooling mode, indoor fan runs all the time and the speed can be selected as high,
medium, low and auto.
2) Auto fan in cooling mode acts as follow:
9.5.7 Condenser high temperature protection function(in cooling and drying mode)
If T3>60℃ for 5 seconds, compressor will stop immediately, and the machine will not resume until T3
<52℃.

9.6 Drying mode

9.6.1
Indoor fan speed is fixed at breeze grade and can't be changed. The horizontal angle is the same as in
cooling mode.
9.6.2
Room overlow temperature protection
In drying mode, if room temperature is lower than 10℃, compressor will stop and not resume until room
temperature climbs up to 12℃.
9.6.3
Evaporator anti-freezing protection, condenser high temperature protection and outdoor unit frequency limit
are valid, and they are the same as that in cooling mode.
9.6.4
Horizontal louver action is the same as that in cooling mode.

9.7 Heating mode

9.7.1
1) Anti-cold-wind function.
Indoor fan operation rule.
4.0
3.0
1.5
1.0
Indoor fan action:
high
medium
low
23