WPA CO 8000 Cell Density Meter
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CO 8000 and is the answer not in the manual?

Questions and answers

Razavi
May 23, 2025

Guten Tag , Ich **** Sie um eine Angebot für Diese Gerät. ( sehr eilig) Vielen Dank ,

Subscribe to Our Youtube Channel

Summary of Contents for WPA CO 8000

  • Page 1 WPA CO 8000 Cell Density Meter User Manual...
  • Page 2: Declaration Of Conformity

    Biochrom Ltd Certificate No. 890333 Declaration of Conformity This is to certify that the WPA CO 8000 Biowave Cell Density Meter Part number 80-3000-45 manufactured by Biochrom Ltd. conform to the requirements of the following Directives-: 73/23/EEC & 89/336/EEC Standards to which conformity is declared...
  • Page 3: Table Of Contents

    CONTENTS Unpacking, Positioning and Installation OPERATION Introduction Using the Instrument Making a measurement Using the memory function TROUBLE SHOOTING NOTES ACCESSORIES OUTPUT OF RESULTS Use with serial printer Use with PC CLEANING AND GENERAL CARE OF THE INSTRUMENT 7 De-contamination procedure SPECIFICATION AND WARRANTY...
  • Page 5: Unpacking, Positioning And Installation

    • The battery will last approx. 1 month when fully charged with normal use. • A full battery recharge will take approx. 12 hours (overnight). ___________________________________________________________________ Issue 03 - 06/2004 WPA CO 8000, English...
  • Page 6: Operation

    A 600nm LED source in combination with a fibre optic is used to obtain the measurement. The instrument can be linked via a serial lead to either a serial printer for hardcopy output or to a PC for download of results to spreadsheet. ___________________________________________________________________ WPA CO 8000, English Issue 03– 06/2004...
  • Page 7: Using The Instrument

    Macro Cuvette 1.0ml 80-3000-60 14mm (max fill volume 4.5ml) Semi-micro 0.5ml 80-3000-76 13mm (max fill volume 1.4ml) 10mm diameter tube 0.9ml 16mm 12mm diameter tube 1.1ml 15mm 16mm diameter tube 2.2ml 15mm ___________________________________________________________________ Issue 03 - 06/2004 WPA CO 8000, English...
  • Page 8: Making A Measurement

    If no further action is taken the screen will revert to its normal state after 7 seconds. If reset is pressed again whilst the screen is flashing all of the memory positions will be cleared. ___________________________________________________________________ WPA CO 8000, English Issue 03– 06/2004...
  • Page 9: Trouble Shooting Notes

    0.8 OD. A simple conversion factor can be calculated from the OD600 of your existing instrument compared to that of the cell density meter IMPORTANT WARNING Always wear protective clothing when handling bacteria or other cells. ___________________________________________________________________ Issue 03 - 06/2004 WPA CO 8000, English...
  • Page 10: Accessories

    Interface Software installed (80-2112-23) and the two are linked with the serial cable (80-3001-00); detailed instructions are supplied with the software. Baud rate is 9600 and the separator should be set to space. ___________________________________________________________________ WPA CO 8000, English Issue 03– 06/2004...
  • Page 11: Cleaning And General Care Of The Instrument

    (taking care to not drop the battery inside the instrument). The contaminated areas in the instrument may then be wiped with a suitable anti-bacterial detergent. ___________________________________________________________________ Issue 03 - 06/2004 WPA CO 8000, English...
  • Page 12: Specification And Warranty

    This product has been designed and manufactured by Biochrom Ltd, 22 Cambridge Science Park, Milton Road, Cambridge CB4 0FJ, UK. ___________________________________________________________________ WPA CO 8000, English Issue 03– 06/2004...