Mitsubishi Electric MXZ-8B140VA Technical & Service Manual page 51

Split-type, heat pump air conditioners
Hide thumbs Also See for MXZ-8B140VA:
Table of Contents

Advertisement

SW2 setting
Indoor pipe temperature / Liquid on
error occurring
– 39~88
ON
1
2 3 4 5 6
Indoor pipe temperature / Cond./ Eva.
on error occurring
– 39~88
ON
1
2 3 4 5 6
Outdoor pipe temperature / 2-phase
(TH6) on error occurring
ON
– 39~88
1
2 3 4 5 6
Outdoor outside temperature (TH7) on
error occurring
ON
– 39~88
1
2 3 4 5 6
Outdoor heatsink temperature (TH8) on
error occurring
ON
– 40~200
1
2 3 4 5 6
Discharge superheat on error occurring
SHd
0~255
ON
1
2 3 4 5 6
Sub-cool on error occurring. SC
0~130
ON
1
2 3 4 5 6
OCH480A
Display detail
SW1
4
5
Indoor unit 1
0
0
Indoor unit 2
1
0
Indoor unit 3
0
1
Indoor unit 4
1
1
Indoor unit 5
0
0
Indoor unit 6
1
0
Indoor unit 7
0
1
Indoor unit 8
1
1
SW1
4
5
Indoor unit 1
0
0
Indoor unit 2
1
0
Indoor unit 3
0
1
Indoor unit 4
1
1
Indoor unit 5
0
0
Indoor unit 6
1
0
Indoor unit 7
0
1
Indoor unit 8
1
1
51
The black square (
Explanation for display
– 39~88
(When the temperature is 0 °C or less, "–" and
6
temperature are displayed by turns.)
0
0
(Example)
0
When –15 °C; 0.5 secs.
0
1
1
1
1
– 39~88
(When the temperature is 0 °C or less, "–" and
temperature are displayed by turns.)
6
0
(Example)
0
When –15 °C; 0.5 secs.
0
0
1
1
1
1
– 39~88
(When the temperature is 0 °C or less, "–" and
temperature are displayed by turns.)
(Example)
When –15 °C; 0.5 secs.
– 39~88
(When the temperature is 0 °C or less, "–" and
temperature are displayed by turns.)
(Example)
When –15 °C; 0.5 secs.
– 40~200
(When the temperature is 0 °C or less, "–" and
temperature are displayed by turns.)
(When the temperature is 100 °C or more, hundreds
digit, tens digit and ones digit are displayed by
turns.)
0~255
(When the temperature is 100 °C or more, hundreds
digit, tens digit and ones digit are displayed by
turns.)
(Example)
When 150 °C; 0.5 secs.
1
0~130
(When the temperature is 100 °C or more, hundreds
digit, tens digit and ones digit are displayed by
turns.)
(Example)
When 115 °C; 0.5 secs.
1
) indicates a switch position.
0.5 secs.
2 secs.
15
0.5 secs.
2 secs.
15
0.5 secs.
2 secs.
15
0.5 secs.
2 secs.
15
0.5 secs.
2 secs.
50
0.5 secs.
2 secs.
15
Unit
:
:
:
:
:
:
: