Control this projector by using a personal computer (Continue)
6) Warning commands
Read the recent warning data and the past warning data. The personal computer doesn't attach the data code
onto the warning commands to send. On the other hand, the projector which has received a command, attach the
warning data as the data code to reply.
Recent data
past data
clear past data
The recent warning data*
EN* (* is 2 digits, hexadecimal notation)
*=(MBS)b1,b2,b3,b4,b5,b6,b7,0(LSB)
b1=Malfunction of the projector.
b2=The lamp is not illuminating.
b3=The lamp cover is not closed.
b4=The filter cover is not closed.
b5=Abnormal temperature (Outside)
b6=Abnormal temperature (the lamp)
b7=Abnormal temperature (Outside)
The past data
Ep* (* is 6 digits, hexadecimal notation)
*=(MBS)b1,b2,b3,b4,b5,b6,b7,0(LSB)
b1=Operation time (during boot up '0' / when the power is ON, '1')
b2=Standby power short
b3=Switch power short
b4=Exausting fan (under the lamp) is stopped.
b5=Inhalation fan is stopped
b6=Exausting fan (under the liquid cristal) is stopped.
b7=Inhalation fan (Under the power box) is stopped.
b8=The lamp cover is not closed.
b9=The filter cover is not closed.
b10=The temperature sensor is off (Exausting fan)
b11=The temperature sensor is off (The lamp)
b12=Communication erro between microcomputer
b13=0
b14=Abnormal temperature (the lamp)
b15=Abnormal temperature (outside)
b16=Abnormal temperature (MAIN circulated board)
b17=The lamp is not illuminating.
b18=0
b19=0
b20=0
b21= The life of a lamp
[Example 1]
The projector was broken when the warning status was confirmed.
Sending commands
from the PC etc.
30 30 45 6E OD
'0' '0' 'E' 'n' '
'
[Example 2]The exausting fan was broken when the power was ON and the past data of the warning was
confirmed.
Sending commands
from the PC etc.
30 30 45 70 OD
'0' '0' 'E' 'p' '
'
ASCII
HEX
En
45h
6Eh
Ep
45h
70h
Ec
45h
63h
Status code from
projector
30 30 45 6E 38 30 0D
'0' '0' 'E' 'n' '8' '0' '
'
Status code from
projector
30 30 45 70 38 38 30 30 30 30 0D
'0' '0' 'E' 'p' '8' '8' '0' '0' '0' '0' '
Meaning
Commnd for confirm resent data
Warning command (Malfunction of
the projector) carried out
Meaning
Commnd for confirm past data
Warning command (Inhalation fan is
'
stopped when the power is ON) carried out