® ABLELink SE5002 Ethernet Serial Server User’s Manual Version 1.3 Updated on 2008/02/29 Tel: 886-3-5508137 Fax: 886-3-5508131 http://www.atop.com.tw...
Ethernet Serial Server SE5002 Important Announcement The information contained in this document is the property of Atop Technologies, Inc. and is supplied for the sole purpose of the operation and maintenance of products of Atop Technologies, Inc. No part of this...
It is essential that only the supplied power cord can be used. Use only shielded cables to connect the device’s ’ RS-232 or RS-485 port. Be cautioned that changes or modifications not explicitly approved by ATOP Technologies could void your authority to operate the equipment.
Page 6
Ethernet Serial Server SE5002 4.1.3 Limitation..........................29 4.1.4 Installation..........................29 4.1.5 Uninstalling..........................29 4.2 Virtual COM communications ....................29 4.2.1 Enabling Virtual COM on SE5002 ...................29 Fig. 36. Enabling Virtual COM port....................29 Fig. 37. Enabling Virtual COM port via Telnet................30 4.2.2 Running Serial/IP on PC ......................30 Fig.
The SE 5002 Series can be operated in one of the following 4 modes: TCP Server Mode:SE5002 can be configured in a TCP server mode on an Ethernet Network to wait for the host computer to establish a connection with the serial device ( the client). After the connection is established, data can flow in both directions (Fig.1 TCP Server Mode).
ABLELink Ethernet Serial Server SE5002 TCP Client Mode:SE5002 can be configured in a TCP client mode on a TCP/IP Network to actively establish a connection with an applications server –the host computer. After the connection is established, data can flow in both directions (Fig 2 TCP Client Mode).
Hardware Description 1.3. NOTE: 1. Model SE5002 is for RS-232/422/485 without isolation protection built-in; SE5002-S55is is for RS422/485 with isolation protection built-in. See Appendix A.3.1 for full Panel layout. 2. Press the reset button to reset to the default values Fig.
Table 3. RUN LED Status 2.2 Installation Procedures: Step 1: Connect SE5002 power source Jack. (Or to a 9~30VDC Terminal Block power source which only for SE5002-S55is) Step 2: Connect SE5002 to the Ethernet network. Use a standard straight-through Ethernet cable when connected to a hub/switch, or connect to a PC‘s Ethernet port via a cross-over Ethernet cable.
A DHCP server can automatically assign the IP address and all the network settings, and SE5002 supports the DHCP client functions. By default, the DHCP client function on SE5002 is disabled; one may activate the DHCP client functions by the following steps:...
Fig. 10. System main menu Notes: 1. If the SE5002 does not receive any command within 1 minute, Telnet will be terminated automatically. 2. The changes of networking parameters will take effect only after the SE 5002 is exited and restarted.
: Input error retrying time on “Please input waiting time for error retrying (0 minute,1~255) ” ( 0->disable the function; 2 ->SE5002 trying to reconnect per 2 minutes) Double click “Enter” key : Input idle time on “Please input idle time to send TCP keep-alive packet (4*10sec) ”( 2->...
Packet delimiter is a way of controlling the number of packets in a serial communication. It is designed to keep packets intack. SE5002 provides two ways in parameter setting: 1. Packet delimiter timer and 2 . Character pattern terminator . By default, packet delimiter timer is 1 ms. The range of packet delimiter timer is 0 to 30,000 msec, as shown in Fig.
Make sure the PC is on the same network as SE5002 Open a web browser, then Enter in the same IP address as the SE5002. The default user name is admin and the default password is null (leave it blank).
TCP/IP field. Alternatively, click on DHCP to obtain auto IP address, gateway and subnet mask. Enable SNMP by checking “Enable”; fill in network identification information on SNMP and click on the “Save Configuration” button to save the changes. The changes will not become effective until SE5002 is restarted (Fig. 25) Fig.
Fig. 26. Com1 setup-TCP server Notes: 1. Default COM1 of SE5002 is 4660 (COM2 is 4661) and it is associated with the serial port COM1 or COM2. After the application program being connected to the TCP port 4660 on the SE5002, data of ones application program are transparent to both COM1 and SE5002.
Fig. 28. Com1 setup –pair connection 3.3.7 Configuring SE5002 in UDP mode: SE5002 can be configured on a UDP mode to establish connection using unicast or broadcast data from the serial device to one or multiple host computer. Vice versa is also true.
Slave (Server) Mode:To establish a connection using unicast or broadcast data from one or multiple host computer to a serial device.(Fig. 32) Notes:The configuration is limited by the Local Listening Port (For example, on the SE5002 listening the port is 4660 which receives data from the Host Computer).
SE5002 via LAN. By creating virtual COM ports on the PC, the Virtual COM driver redirects the communications from the virtual COM ports to an IP address and port number on a SE5002 that connects the serial line device to the network. Fig. 35 illustrates a Virtual COM connection diagram.
4.2.1 Enabling Virtual COM on SE5002 From the web browser, access SE5002 by typing its IP address. Click on COM1 link to access COM1 window. On the window, click on “TCP Server” and check “Enable” button. Then Enter in the local port number on “Local Port”...
ETUP 5.1 SNMP Network Management Platform SE5002 is an SNMP device that allows many popular SNMP Network management platforms such as HP Open View and Sun Net Manager, to conduct on the SerialManager. Depending on the network management tools used, SE5002 information can be collected from running the management tools, including IP address, DNS name, system descriptions and NIC information.
Hardware Installation). 3. Configure SE5002 as TCP Server, using the default TCP port number 4660. 4. The host (PC) application program must be configured as a TCP client and connected to SE5002 with designated TCP port number 4660 for COM1.
Always use '=' then Enter key to exit the program. 7 Diagnostics There are several ways to check the status and availability of SE5002. 7.1 Using Standard TCP/IP Utility ping Command Go to Windows Start menu, select Run and Enter in “ping <TCP Server IP address>”.
Ethernet Serial Server SE5002 7.2 Using SerialManager Configuration Utility Program Use SerialManager configuration program on the product CD to check the status of SE5002. The status and version can be read from the tool. For example, ‘S’ means that COM1 is in server mode and is not connected.
User manual Version 1.3 ® ABLELink Ethernet Serial Server SE5002 A.3.1.2 SE5002-S55is (RS-422/RS-485) A.3.2.1 DB9 Pin Assignments The pin assignments of DB9 connector on SE5002 are shown in the following table: RS-232 RS-485/RS422 RS-485 Pin# Full Duplex 2 wire, Half Duplex...
User manual Version 1.3 ® ABLELink Ethernet Serial Server SE5002 A.3.2.2 Terminal Block Pin Assignments The pin assignments of Terminal Block connector on SE5002-S55is are shown in the following table: RS-485/RS-422 RS-485 Pin# 4 wire, Half Duplex 2 wire, Full Duplex...
B.1 System Upgrade Procedure 1. Make sure the PC and the SE5002 are on the same network. Use command ping or SerialManager program to verify their availability. 2. Prepare the download tool and press any key to edit the configuration file dapdl.cfg.
1. The upgrading process can be aborted by pressing the <Esc> key. SE5002 will restart automatically and the system remains the same. 2. If SE5002 does not receive any upgrading data within 30 seconds, it will restart automatically and the system remains the same.
Ethernet Serial Server SE5002 Appendix C: Re-loading System Firmware The AP (application program) firmware of SE5002 can be disabled If a wrong version is downloaded. To disable the current version of firmware and re-load the correct one, do the followings: 1.