ABLELink SE5002 User Manual

Ethernet serial server
Hide thumbs Also See for SE5002:
Table of Contents

Advertisement

Quick Links

®
ABLELink
SE5002 Ethernet Serial Server
User's Manual
Version 1.3
Updated on 2008/02/29
Tel: 886-3-5508137
Fax: 886-3-5508131
http://www.atop.com.tw

Advertisement

Table of Contents
loading

Summary of Contents for ABLELink SE5002

  • Page 1 ® ABLELink SE5002 Ethernet Serial Server User’s Manual Version 1.3 Updated on 2008/02/29 Tel: 886-3-5508137 Fax: 886-3-5508131 http://www.atop.com.tw...
  • Page 2: Important Announcement

    Ethernet Serial Server SE5002 Important Announcement The information contained in this document is the property of Atop Technologies, Inc. and is supplied for the sole purpose of the operation and maintenance of products of Atop Technologies, Inc. No part of this...
  • Page 3: Fcc Warning

    It is essential that only the supplied power cord can be used. Use only shielded cables to connect the device’s ’ RS-232 or RS-485 port. Be cautioned that changes or modifications not explicitly approved by ATOP Technologies could void your authority to operate the equipment.
  • Page 4: Table Of Contents

    TCP Client Mode .........................8 Fig. 3. UDP Mode ...........................8 Fig. 4. Tunneling Mode ........................9 1.3. Hardware Description ................9 Fig. 5. SE5002 Interfaces and DIN-Rail Mounting settings ............10 2. LED S ....................10 TATUS LAN ............................10 Installation Procedures:......................10 3. S .......................10...
  • Page 5 3.3.2 Changing password ........................20 Fig. 24. Change the password .....................21 3.3.3 Networking..........................21 Fig. 25. Network setup ........................21 3.3.4 Configuring SE5002 as TCP server: ..................22 Fig. 26. Com1 setup-TCP server ....................23 3.3.5 Configuring SE5002 as TCP client: ..................23 Fig. 27. Com1 setup-TCP client ....................24 3.3.6 Pair Connection(Tunneling Mode) ...................24...
  • Page 6 Ethernet Serial Server SE5002 4.1.3 Limitation..........................29 4.1.4 Installation..........................29 4.1.5 Uninstalling..........................29 4.2 Virtual COM communications ....................29 4.2.1 Enabling Virtual COM on SE5002 ...................29 Fig. 36. Enabling Virtual COM port....................29 Fig. 37. Enabling Virtual COM port via Telnet................30 4.2.2 Running Serial/IP on PC ......................30 Fig.
  • Page 7 B.3 Error Messages ........................... 43 Appendix C: Re-loading System Firmware ..........44 Appendix D: Using SerialManager...............44 D.1. SerialManager Introduction ...................... 44 D.2. Interface............................. 44 D.3. Functions ........................... 45 Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan. - 6 -...
  • Page 8: Introduction

    The SE 5002 Series can be operated in one of the following 4 modes: TCP Server Mode:SE5002 can be configured in a TCP server mode on an Ethernet Network to wait for the host computer to establish a connection with the serial device ( the client). After the connection is established, data can flow in both directions (Fig.1 TCP Server Mode).
  • Page 9: Fig. 2. Tcp Client Mode

    ABLELink Ethernet Serial Server SE5002 TCP Client Mode:SE5002 can be configured in a TCP client mode on a TCP/IP Network to actively establish a connection with an applications server –the host computer. After the connection is established, data can flow in both directions (Fig 2 TCP Client Mode).
  • Page 10: Fig. 4. Tunneling Mode

    Hardware Description 1.3. NOTE: 1. Model SE5002 is for RS-232/422/485 without isolation protection built-in; SE5002-S55is is for RS422/485 with isolation protection built-in. See Appendix A.3.1 for full Panel layout. 2. Press the reset button to reset to the default values Fig.
  • Page 11: Led Status Lan

    Table 3. RUN LED Status 2.2 Installation Procedures: Step 1: Connect SE5002 power source Jack. (Or to a 9~30VDC Terminal Block power source which only for SE5002-S55is) Step 2: Connect SE5002 to the Ethernet network. Use a standard straight-through Ethernet cable when connected to a hub/switch, or connect to a PC‘s Ethernet port via a cross-over Ethernet cable.
  • Page 12: Configuration By Serialmanager

    A DHCP server can automatically assign the IP address and all the network settings, and SE5002 supports the DHCP client functions. By default, the DHCP client function on SE5002 is disabled; one may activate the DHCP client functions by the following steps:...
  • Page 13: Fig. 8. Serialmanager Auto Ip Dialog Window

    Fig. 10. System main menu Notes: 1. If the SE5002 does not receive any command within 1 minute, Telnet will be terminated automatically. 2. The changes of networking parameters will take effect only after the SE 5002 is exited and restarted.
  • Page 14: Fig. 11. System Configuring Using Telnet

    This system overview window gives the general information on IP, MAC address, SNMP information, kernel and AP version, and the connection status of the device. Select “2” on “Input choice and enter (0~5):” to enter Networking window (Fig. 12). Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan. - 13 -...
  • Page 15: Fig. 12. Network Configuring Using Telnet

    , and again on “Please verify new password” fields. Note: One may press the Reset key on the product to reset password. Select “4” on “Input choice and enter (0~5):” (Fig. 14). Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan. - 14 -...
  • Page 16: Fig. 14. Com1 Setup

    “IP filtering function is disabled by setting FILTER_IP to “0.0.0.0”. IP filter is disabled by default If IP filter is enabled, only the source IP assigned can be connected to SE5002. Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan.
  • Page 17: Fig. 15. Link Mode-Tcp Server Setup

    : Input error retrying time on “Please input waiting time for error retrying (0 minute,1~255) ” ( 0->disable the function; 2 ->SE5002 trying to reconnect per 2 minutes) Double click “Enter” key : Input idle time on “Please input idle time to send TCP keep-alive packet (4*10sec) ”( 2->...
  • Page 18: Fig. 16. Link Mode-Tcp Client Setup

    In this example the local port is 4660; the destination IP is 10.0.29.254, and the destination port is 666(Fig. 17) Fig. 17. Link Mode-UDP client setup Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan. - 17 -...
  • Page 19: Fig. 18. Com Port Setting

    Packet delimiter is a way of controlling the number of packets in a serial communication. It is designed to keep packets intack. SE5002 provides two ways in parameter setting: 1. Packet delimiter timer and 2 . Character pattern terminator . By default, packet delimiter timer is 1 ms. The range of packet delimiter timer is 0 to 30,000 msec, as shown in Fig.
  • Page 20: Fig. 20. Setting Packet Delimiter Timer

    Make sure the PC is on the same network as SE5002 Open a web browser, then Enter in the same IP address as the SE5002. The default user name is admin and the default password is null (leave it blank).
  • Page 21: Fig. 22. Login The System Via Web

    The following overview screen shall appear (Fig. 23) Fig. 23. Overview 3.3.2 Changing password 1. Click on the “Security” link and the following screen shall appear (Fig. 24) Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan. - 20 -...
  • Page 22: Fig. 24. Change The Password

    TCP/IP field. Alternatively, click on DHCP to obtain auto IP address, gateway and subnet mask. Enable SNMP by checking “Enable”; fill in network identification information on SNMP and click on the “Save Configuration” button to save the changes. The changes will not become effective until SE5002 is restarted (Fig. 25) Fig.
  • Page 23: Configuring Se5002 As Tcp Server

    IP filtering function is disabled by setting FILTER_IP to “0.0.0.0”. IP filter is disabled by default If IP filter is enabled, only source IP assigned is connected to SE5002. Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan.
  • Page 24: Fig. 26. Com1 Setup-Tcp Server

    Fig. 26. Com1 setup-TCP server Notes: 1. Default COM1 of SE5002 is 4660 (COM2 is 4661) and it is associated with the serial port COM1 or COM2. After the application program being connected to the TCP port 4660 on the SE5002, data of ones application program are transparent to both COM1 and SE5002.
  • Page 25: Fig. 27. Com1 Setup-Tcp Client

    Fig. 27. Com1 setup-TCP client 3.3.6 Pair Connection(Tunneling Mode) Pair connection is for two or more serial connections with their own SE5002’s to send data over Ethernet to communicate with each other. To do so, choose “pair connection” indicated in Fig. 28 Copyright ©...
  • Page 26: Fig. 28. Com1 Setup –Pair Connection

    Fig. 28. Com1 setup –pair connection 3.3.7 Configuring SE5002 in UDP mode: SE5002 can be configured on a UDP mode to establish connection using unicast or broadcast data from the serial device to one or multiple host computer. Vice versa is also true.
  • Page 27: Fig. 29. Com 1 Setup –Udp Mode

    Host Computer #3 IP: 192.168.1.200 Listening Port 666 Host Computer #4 IP: 192.168.1.254 Listening Port 666 Fig. 31. Data Transmission in a UDP Master(Client) Mode Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan. - 26 -...
  • Page 28: Fig. 32. Data Transmission In A Udp Slave(Server) Mode

    Slave (Server) Mode:To establish a connection using unicast or broadcast data from one or multiple host computer to a serial device.(Fig. 32) Notes:The configuration is limited by the Local Listening Port (For example, on the SE5002 listening the port is 4660 which receives data from the Host Computer).
  • Page 29: Using Virtual Com

    SE5002 via LAN. By creating virtual COM ports on the PC, the Virtual COM driver redirects the communications from the virtual COM ports to an IP address and port number on a SE5002 that connects the serial line device to the network. Fig. 35 illustrates a Virtual COM connection diagram.
  • Page 30: Setup Of A Virtual Com Driver

    4.2.1 Enabling Virtual COM on SE5002 From the web browser, access SE5002 by typing its IP address. Click on COM1 link to access COM1 window. On the window, click on “TCP Server” and check “Enable” button. Then Enter in the local port number on “Local Port”...
  • Page 31: Fig. 37. Enabling Virtual Com Port Via Telnet

    On Window Start Menu, go to \program\serial/IP for ATOP\control panel\Select Port\, then select the serial port. Then the “ Serial I/P for Atop Control Panel” window appears (Fig. 38). Fig. 38. Serial/IP for Atop control panel Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan. - 30 -...
  • Page 32: Configuring Virtual Com Ports

    7. On COM Port Options, the settings must match the COM port behavior expected by the PC application. The Configuration Wizard will recommend such settings. Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan. - 31 -...
  • Page 33: Snmp Setup

    ETUP 5.1 SNMP Network Management Platform SE5002 is an SNMP device that allows many popular SNMP Network management platforms such as HP Open View and Sun Net Manager, to conduct on the SerialManager. Depending on the network management tools used, SE5002 information can be collected from running the management tools, including IP address, DNS name, system descriptions and NIC information.
  • Page 34: Fig. 42. Networkview Display The Devices Found

    Fig. 43. NetworkView display device information Notes: NetworkView is limited to information extracting and viewing only. To modify the configurations, use the web server, Telnet or SerialManager configuration utilities. Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan. - 33 -...
  • Page 35: Preparing System

    Hardware Installation). 3. Configure SE5002 as TCP Server, using the default TCP port number 4660. 4. The host (PC) application program must be configured as a TCP client and connected to SE5002 with designated TCP port number 4660 for COM1.
  • Page 36: Tcptest2 In Visual C

    Always use '=' then Enter key to exit the program. 7 Diagnostics There are several ways to check the status and availability of SE5002. 7.1 Using Standard TCP/IP Utility ping Command Go to Windows Start menu, select Run and Enter in “ping <TCP Server IP address>”.
  • Page 37: Using Tcptest.exe Or Tcptest2.Exe Sample Program

    Ethernet Serial Server SE5002 7.2 Using SerialManager Configuration Utility Program Use SerialManager configuration program on the product CD to check the status of SE5002. The status and version can be read from the tool. For example, ‘S’ means that COM1 is in server mode and is not connected.
  • Page 38 +9~30VDC Jack or DC +9~30V Terminal Block, 2.8 Watt Max ℃ ℃ Temperature Operation: to 60 ℃ ℃ Storage: to 70 Humidity 20%~90% non-condensing Housing 90mm(L) x 45mm(W) x 63mm(H) Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan. - 37 -...
  • Page 39: Software Specification

    RS-232 or RS-485/RS-422 receiving buffer size = 4K bytes RS-232 or RS-485/RS-422 transmitting buffer size = 4K bytes A.3 Panel Layout and Connector Pin Assignments A.3.1. Panel Layout A.3.1.1 DB9 for SE5002 (RS-232/RS-422/RS-485) Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan. - 38 -...
  • Page 40: Db9 Pin Assignments

    User manual Version 1.3 ® ABLELink Ethernet Serial Server SE5002 A.3.1.2 SE5002-S55is (RS-422/RS-485) A.3.2.1 DB9 Pin Assignments The pin assignments of DB9 connector on SE5002 are shown in the following table: RS-232 RS-485/RS422 RS-485 Pin# Full Duplex 2 wire, Half Duplex...
  • Page 41: Terminal Block Pin Assignments

    User manual Version 1.3 ® ABLELink Ethernet Serial Server SE5002 A.3.2.2 Terminal Block Pin Assignments The pin assignments of Terminal Block connector on SE5002-S55is are shown in the following table: RS-485/RS-422 RS-485 Pin# 4 wire, Half Duplex 2 wire, Full Duplex...
  • Page 42: Note: Device Will Not Be Damage If The Polarity Is Reverse

    Jumper JP1 pin1 and pin2 are shorted to disable AP firmware in the flash memory. LED blinking (rate: 0.5Sec) AP firmware is running Table 4. RUN LED Message Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan. - 41 -...
  • Page 43: Appendix B: Upgrade System Firmware

    B.1 System Upgrade Procedure 1. Make sure the PC and the SE5002 are on the same network. Use command ping or SerialManager program to verify their availability. 2. Prepare the download tool and press any key to edit the configuration file dapdl.cfg.
  • Page 44: Critical Issues

    1. The upgrading process can be aborted by pressing the <Esc> key. SE5002 will restart automatically and the system remains the same. 2. If SE5002 does not receive any upgrading data within 30 seconds, it will restart automatically and the system remains the same.
  • Page 45: Appendix C: Re-Loading System Firmware

    Ethernet Serial Server SE5002 Appendix C: Re-loading System Firmware The AP (application program) firmware of SE5002 can be disabled If a wrong version is downloaded. To disable the current version of firmware and re-load the correct one, do the followings: 1.
  • Page 46: Functions

    The user can select his required search way by clicking the Search option on the main menu, shown as below: Or, select by clicking a button on the toolbar, as below: Broadcast Rescan Search Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan. - 45 -...
  • Page 47 Once Search by IP Address is selected, an interface will pop up as below: Here user may have two options: Select an IP address to search or Search device in the range of IP address. Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan. - 46 -...
  • Page 48 MAC address D3.1.4 Rescan Once the user click the Rescan button on the toolbar, the SerialManager shall re-search devices by using the current search way. Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan. - 47 -...
  • Page 49 ABLELink Ethernet Serial Server SE5002 D3.2 Firmware This function is applied to downloading a firmware into a selected device. Upgrade from disk Upgrade from disk Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan. - 48 -...
  • Page 50 The user can also select several same devices at one time, and realize the firmware updating for them by selecting Apply for all selected devices have same model. Download Parameter Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan. - 49 -...
  • Page 51 Here three functions are mainly supplied, including: Login, Logout and Change Password, shown as the figure below: Login Logout Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan. - 50 -...
  • Page 52 This function is applied to modifying the password for logging in any network device, but can only be realized after a successful log-in, shown as the figure below: Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan.
  • Page 53 Locate Network Import Export … Port … Setting … Setting … Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan. - 52 -...
  • Page 54 COM port parameters. Note: This function can be realized only after a successful login, shown as the figure below: Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan.
  • Page 55 The user can set each corresponded connecting mode and the working parameter by clicking the button "Option", shown as the figure below: Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan.
  • Page 56 Flash through the submenu option Erase Flash or clicking the Erase Flash button on the toolbar when the memory capacity is to be used up or the history data are unnecessary to be saved. Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan.
  • Page 57 The user can also select several devices at one time, and lead the parameter information of a standard parameter file into all the selected devices by selecting Apply for all selected devices have same model. Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan.
  • Page 58 Some devices are supplied with the function of virtual serial port, and the user can carry out any related setting through the submenu option "Virtual COM", shown as the figure below: Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan.
  • Page 59 "View", such as: display in sequence of device module name, or display in sequence of IP address and so on, shown as the figure below: Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan. - 58 -...
  • Page 60 ABLELink Ethernet Serial Server SE5002 D3.6 Help This function is mainly applied to displaying some help information of the SerialManager, shown as the figure below: Copyright © 2006 Atop Technologies, Inc. All rights reserved. Designed in Taiwan. - 59 -...