INIMUM GAS PRESSURE SETTING
Not applicable for premix burner (only for atmospheric burner)
P
.10 – M
ARAMETER NO
INIMUM CENTRAL HEATING OUTPUT SETTING
Not applicable for premix burner (only for atmospheric burner)
P
.11 – M
ARAMETER NO
AXIMUM GAS PRESSURE AND MAX
Not applicable for premix burner (only for atmospheric burner)
P
.12 –
ARAMETER NO
IGNITION SEQUENCE SETTING
Not applicable for premix burner (only for atmospheric burner)
REGULATION INSTRUCTIONS
P
7 – C
ARAMETER
6. Use buttons '+' and '-' to modify the value of the parameter within
120 60 Hz
prescribed limits
00 = 0 x 5" = 0"
90 = 90 x 5" = 450" (7.5 min)
The default value is 36 = 180" = 3 min
7. Press and release button 'S' to confirm. The parameter number (7)
will appear on the display.
120 60 Hz
8. Switch off the appliance and switch it back on again to render the
new parameter operative.
P
8 – D.H.W
ARAMETER
6. Use buttons '+' and '-' to modify the value of the parameter within
120 60 Hz
prescribed limits
00 = 0 x 5" = 0"
90 = 90 x 5" = 450" (7.5 min)
The default value is 18 = 90" = 1.5 min
7. Press and release button 'S' to confirm. The parameter number (8)
will appear on the display.
120 60 Hz
8. Switch off the appliance and switch it back on again to render the
new parameter operative.
.
ENTRAL HEATING PUMP OVERRUN TIMER
PUMP OVERRUN TIMER
CENTRAL HEATING OUTPUT SETTING
43