Lcd Diagnostic Messages; Maintenance Reminders; Marquis Spa Care - Marquis Spas Owner's Manual

Hide thumbs Also See for Marquis Spas:
Table of Contents

Advertisement

After the power is turned back on, the spa will not restart itself until the water
temperature within the spa drops to a lower, predetermined temperature.
OHS, OH: Over heat protection. The spa has shut down. One of the sensors
has detected that the spa water is 43.3°C. DO NOT ENTER THE WATER. Turn
off all power to the spa. Remove spa cover and allow water to cool. Once the
heater has cooled, turn on power to spa, then reset by pushing any pad. If spa
does not reset, shut off the power to the spa and contact authorized Marquis
Spas
dealer for service.
®
ICE, IC: Freeze protection has been activated. Contact your authorized Marquis
Spas
dealer for service. NOTE: ICE can been seen on a fresh fill if water
®
temperature is too cold.
SnA and SA: A sensor that is plugged into the Sensor "A" jack is not working.
The spa turns off. Contact authorized Marquis Spas
Snb and SB: A sensor that is plugged into the Sensor "B" jack is not working.
The spa turns off. Contact authorized Marquis Spas
SnS and SN: Sensors are out of balance. If this is alternating with the
temperature, it may just be a temporary condition. If the display shows only this
message (periodically blinking), the spa is shut down. Contact authorized
Marquis Spas
dealer for service.
®
NOTE: If power is shut off or a power outage occurs, the 240V system has a
battery backup. All user settings are retained.
HFL and HL: A substantial difference between the temperature sensors was
detected. This could indicate a flow problem. Check water level in spa. Refill if
necessary. If the water level is okay, make sure the pumps have been primed. If
problem persists, contact authorized Marquis Spas
NOTE: Spas can experience an over heat failure when in Economy or Sleep mode if
equipment is in direct sunlight. To resolve this problem, change to Standard mode
setting.
LF: Persistent low flow problems. (Displays on the fifth occurrence of the HFL
message within 24 hours.) Heater is shut down, but other spa functions continue
to run normally. Following this action is required for HFL message. Heating
capacity of the spa will not reset automatically. You may press any pad to reset.
dr: Inadequate water detected in heater. Check water level in spa. Refill if
necessary. If the water level is okay, make sure the pumps have been primed. Press
any pad to reset.
drY: Inadequate water detected in heater. (Displays on third occurrence of dr
message.) Spa is shut down. Follow action required for "dr" message. Spa will
not automatically reset; you may press any pad to reset.
Pr: When your spa is first energized, it will go into Priming mode. It will last for
up to four or five minutes and then the spa will begin to heat and maintain the
water temperature in the Standard mode.
- - F; - - C: Temperature is unknown. After the pump has been running for two
minutes, the temperature will display.
- - -: The temperature is not current. The spa is in Economy or Sleep mode. The
pump may have been off for hours. If you wish to see the current spa
temperature, either switch to Standard mode or turn Jets 1 on for at least two
minutes.
Additional Diagnostics for Epic and Show models:
rtC: Hardware failure. Contact authorized Marquis Spas
PSt: Hardware failure. Contact authorized Marquis Spas
CrC: Firmware install problem. Contact authorized Marquis Spas
CFE: Configuration error, spa cannot start up. Contact authorized Marquis
Spas
dealer.
®
GFI: Spa can not trip GFCI. Contact dealer. Continued operation could be unsafe.
dealer for service.
®
dealer for service.
®
dealer.
®
dealer.
®
dealer.
®
dealer.
®
®
M A R Q U I S
S P A S
StU: Pump appears to be stuck in the on position, causing the water temperature to
creep up, possibly to hazardous levels. POWER DOWN SPA IMMEDIATELY. DO
NOT ENTER THE WATER. Contact authorized Marquis Spas
HOt: Pump appears to have been stuck in the on position the last time spa was
powered.
POWER DOWN SPA IMMEDIATELY. DO NOT ENTER THE WATER. Contact
authorized Marquis Spas
dealer.
®
NOTE: If power is shut off or a power outage occurs, the 240V system has a
battery backup. All user settings are retained.

MAINTENANCE REMINDERS:

The following reminders will be shown on the LED lights indicating it is time for
maintenance. Reminder messages will also be displayed in the LCD window.
Reset the reminders by pressing the Temp Up, Temp Down, or Settings pad.
• Clean Filter: LED will illuminate every 30 days. rCL will be displayed in the
LCD window.
• Change Water: LED will illuminate every 90 days. rCH will be displayed in the
LCD window.
• Change Minerals: rCA will be displayed in the LCD window every 90 days.
• Check Bromine: rSA will be displayed in the LCD window every 21 days.

MARQUIS SPA CARE

IMPORTANT CHEMICAL SAFETY PROCEDURES
1
Always keep chemicals out of reach of children.
2. Read product labels carefully prior to use.
3. When dissolving, always add chemicals to water; do not add water to
chemicals. Some dry chemicals should be dissolved prior to adding them to
the spa. Dip some water from the spa using a clean container. Mix until
dissolved then add to circulating water.
4. CAUTION: Do not add chemicals together; add them separately to the spa
water.
5. All chemical products should be stored in a cool, dry, well-ventilated area
where the average temperature does not exceed 32°C. Keep storage area
clean of debris such as rags, newspaper, and combustible materials.
6. Keep chemicals away from open flame or other heat source. Do not smoke
near chemicals. If a dry chlorine chemical fire should occur, use water only.
Do not use a dry chemical fire extinguisher to attempt to put out the fire.
7. When adding chemicals, always keep the water circulating in the spa with
jets in a downward circular pattern for better chemical distribution. Add
chemicals to the spa water one at a time. Allow several minutes between
any new chemical additions using the jet action to evenly distribute
throughout the spa.
8. It is important to leave the spa cover open for 20-30 minutes while shock
treating your spa to avoid damage. Do not leave spa unattended while
cover is open. Damage such as discoloration or brittle vinyl due to chemical
damage is not covered under the warranty.
9. After adding chemicals, wait the amount of time recommended on the
chemical container before retesting your water for an accurate reading.
Retest your spa water before using.
10. If you have any questions or concerns about the correct procedures for
handling chemicals, please contact your authorized Marquis Spas® dealer.
WATER CARE
There are three things necessary for clean safe water:
1. CIRCULATE: Water has to be circulated regularly; it can not be stagnant.
2. FILTER: Water has to be filtered to remove particulate and debris.
3. SANITIZE: Water has to be sanitized to kill organisms like algae, bacteria
and virus.
It is critical to maintain proper water balance to protect the spa heater and other
components from damage. Damage to the spa surface and equipment caused
by poor chemical or harsh chemical treatment is not covered under the warranty.
Discoloration of jet faces, valves and controls are an indication of poor chemical
maintenance or exposure to the sun.
Jet inserts and valves do not qualify for labor coverage. These parts can be
purchased or exchanged under warranty at your authorized Marquis Spas
dealer. Gaskets and seals are not covered under the warranty.
O W N E R ' S
M A N U A L
dealer.
®
®
17