Maintenance and repair ....25 specifications, and other information set forth in it, are the exclusive property of Bosch Decommissioning ....25 Rexroth AG.
3 609 929 B47/2008-12 | LTU350/1 Bosch Rexroth AG 17/84 About this document • Always include the operating instructions when you pass the LTU350/1 servo This manual contains important information amplifier on to third parties. on the safe and appropriate assembly,...
Page 4
18/84 Bosch Rexroth AG LTU350/1 | 3 609 929 B47/2008-12 Personnel qualifications This warning symbol cautions Assembly, commissioning and operation, against dangers to your health. disassembly, service (including maintenance Observe all the safety instructions and repair) require basic electrical and...
3 609 929 B47/2008-12 | LTU350/1 Bosch Rexroth AG 19/84 Observe the regulations for accident During commissioning prevention and environmental protection for Let the product acclimate itself for several the country where the product is used and at hours before commissioning, otherwise the workplace.
20/84 Bosch Rexroth AG LTU350/1 | 3 609 929 B47/2008-12 Product description Performance description Device description The LTU350/1 servo amplifier supplies power to and controls the ErgoSpin handheld nutrunner. The speed and current are controlled in the servo amplifier. NOTE!
Page 7
3 609 929 B47/2008-12 | LTU350/1 Bosch Rexroth AG 21/84 Display Table 2 The graphic LC display (Figure 2) enables a Monitoring function Actual value display of the result values (torque, angle, Torque gradient, time) and error codes. Texts are shown in 4 lines, each with 8 characters.
Page 8
22/84 Bosch Rexroth AG LTU350/1 | 3 609 929 B47/2008-12 Language packs XDS1 interface for handheld nutrunner The language pack for the LTU350/1 is uploaded to the controller using the BS350 The tightening spindle is connected to the operating program. This is done via the menu servo amplifier via a spindle connecting cable item “Configuration | HMI SE/CS”...
Page 9
3 609 929 B47/2008-12 | LTU350/1 Bosch Rexroth AG 23/84 Motor contactor control Fuses The intermediate circuit of the servo amplifier is protected by two safety fuses. If these Table 7 Positions of the PIN plug in the LTU350/1 fuses blow (melt), the BTB LED changes from green to red.
24/84 Bosch Rexroth AG LTU350/1 | 3 609 929 B47/2008-12 Transport and storage CAUTION For storing and transporting the product, Risk of injuries when always observe the ambient conditions assembling under voltage! specified in the technical data (see “Technical data” on page 27).
3 609 929 B47/2008-12 | LTU350/1 Bosch Rexroth AG 25/84 Commissioning Maintenance and repair CAUTION Cleaning and care Risk of damage to persons and property! CAUTION Commissioning of the LTU350/1 Any dirt or liquids penetrating servo amplifier requires basic me-...
Therefore, dispose of the device in Disassembling accordance with the currently applicable regulations in your country. CAUTION You can also send the device to Bosch Removing the LTU350/1 servo Rexroth for disposal. amplifier while live Damage to the LTU350/1 servo...
3 609 929 B47/2008-12 | LTU350/1 Bosch Rexroth AG 27/84 Technical data Table 8 Designation LTU350/1 Order number 0 608 750 111 Input voltages From the supply module Intermediate circuit voltage 160 V to 320 V Control voltage + 24 V / – 24 V / 5 V (SELV)