9.
After you complete above configuration procedure, you can start to
develop your application. Press "Build"/ "Build xxx.exe" to com-
pile your program to .exe file and download it to UNO-1019.
10.
If you want to execute your program, press "Build" / "Execute
xxx.exe" and then the program will be executed in UNO-1019.
4.5.2 Watchdog Timer
There is a built-in watchdog timer in UNO-1019. Users can utilize the
WDT driver with standard WIN32 API to implement the watchdog func-
tion in their applications. To use the watchdog driver, firstly user must
open it via the name, "WDT1:", then use DeviceIOControl function to
access the watchdog hardware. The introduction below includes the defi-
nition of DeviceIOControl and its parameters as well as an example.
57
Chapter 4