FACTORY & ELECTRONIC ADJUSTMENT
WARNING: BEFORE SERVICING THIS CHASSIS, READ THE
"X-RAY RADIATION PRECAUTION", "SAFETY PRECAUTION"
AND "PRODUCT SAFETY NOTICE" ON PAGE 1 AND 2 OF THIS
MANUAL.
The following adjustments should be made when a complete realignment is required or a new
picture tube is installed.
Perform the adjustments in order as follows :
1.
Purity
2.
Distortion (Vertical) balance
3.
Convergence
4.
Focus
Note: The PURITY/CONVERGENCE MAGNET assembly and rubber wedges need mechanical
positioning.
CPT
DY
DEFLECTION
YOKE
(DY)
SET-UP ADJUSTMENT
PART DESCRIPTION
Picture tube,
M81AHM50X01
Deflection yoke,
YS-70840
2
40MAX
90MAX
PURITY/
CONVERGENCE
MAGNET ASS'Y
(CPM)
PART NO.
VBM81AHM50X01
RDY-N1004-1----
3
1