Installation Instructions If you have questions, call 800-GE-CARES or visit our website at: www.monogram.com 42" Island Vent Hood Model: ZV1050 Monogram. ® We bring good things to life.
Design Information BEFORE YOU BEGIN WARNING: TO REDUCE THE RISK OF FIRE, ELECTRICAL Read these instructions completely and carefully. SHOCK OR INJURY TO PERSONS, OBSERVE THE • IMPORTANT - Save these instructions for FOLLOWING: local inspector’s use. A. Use this unit only in the manner intended by the •...
Advance Planning TOOLS AND MATERIALS REQUIRED POWER SUPPLY (not supplied) IMPORTANT - (Please read carefully) • Tape measure WARNING: • Knife FOR PERSONAL SAFETY, THIS • Spirit level APPLIANCE MUST BE PROPERLY GROUNDED. • Wire cutter ATTENTION – • Wire stripper POUR DES RAISONS DE •...
* Actual length of straight duct plus duct fitting equivalent. Equivalent length of duct pieces are based Total Duct Run on actual tests conducted by GE Evaluation Engineer- ing and reflect requirements for good venting performance with any ventilation hood.
Installation Instructions STEP 1 ADVANCE PLANNING Ceiling Plan the location Hood Determine the exact location of the vent hood. Ducting Centerline • Use a plumb bob to check location to be sure countertop/cooktop location below the hood will align exactly. •...
Installation Instructions STEP 1 CONTINUED 2x 4 Min. Cross Framing • Arrange cross framing in the ceiling to suit the existing structure. See examples. – Secure each 2 x 4 block with at least four (4), #10 wood screws, 3” long (not supplied). Use 8 wood screws total for the two supports.
Installation Instructions STEP 2 REMOVE THE PACKAGING The vent hood is packed separate from the decorative duct cover or accessory covers ZX1059SFSS or ZX10510SFSS. • Remove the frame, cover, parts box and packaging. • Remove junction box cover. • Install strain relief onto junction box cover. STEP 3 CHECK INSTALLATION HARDWARE Locate the hardware accessory pack shipped with the hood and check contents.
Installation Instruction STEP 4 MOUNT TEMPLATE • Align the template with the marks on the ceiling and tape in place. – Be sure the template is oriented correctly, with the front of the hood. • Use a plumb to check to be sure the mounting holes will provide parallel alignment with the countertop below.
Installation Instructions STEP 6 SECURE WIRING STEP 7 SIZE AND INSTALL DUCTWORK • Route house wiring through the ceiling hole and pull a length to reach the hood junction box, Ceiling approximately 6” below the support. Ceiling House Duct Left Side View Required Side...
Installation Instructions STEP 11 SLIDE DUCT COVER DOWN STEP 10 CONNECT ELECTRICAL Verify that power is turned off at the source. WARNING: If house wiring is not 2-wire with a ground wire, a ground must be provided by the Install installer.
Installation Instructions STEP 12 INSTALL FILTERS, FINALIZE INSTALLATION Filter Slots • Remove protective film on the filters. • Tip the filter into the lower slots at the rear of the opening. Lift the filter and pull the knob forward until the filter rests on the slots. •...
Page 16
Note: While performing installations described in this book, safety glasses or goggles should be worn. ® For Monogram local service in your area, call 1-800-444-1845. Note: Product improvement is a continuing endeavor at General Electric. Therefore, materials, appearance and specifications are subject to change without notice. Monogram.