1. Product Specifications

1-1 Table
Item
Type
Cooling
Heating
Dehumidifying
Air Volume
Perfor-
mance
Noise
( ):EUROVENT
Energy Efficiency Ratio
Power
Power Consumption
Operating Current
Power
Power Factor
Starting Current
Power Cord
Outer
Dimension
Weight
Refrigerant Pipe
Drain Hose
Size
Type
Compressor
Motor
Type
Blower
Motor
Heat Exchanger
Refrigerant Control Unit
Freezer Oil Capacity
Refrigerant to Change(R410A)
Protection Device(OLP)
Cooling Test Condition
Maximum Operation Condition
Samsung Electronics
Model
kW
|/h
Cooling
m
3
/min
Heating
Cooling
dB
Heating
Cooling
W/W
Heating
V-Hz
Cooling
W
Heating
Cooling
A
Heating
Cooling
%
Heating
A
Length
m
Number of Core Wire
Capacity
A
mm
W x H x D
inch
kg
Liquid
mm x L(m)
GAS
mm x L(m)
D(mm)
Type
Rated Output
Type
Rated Output
W
cc
g
SH09AI8R / SH09AI8V
Indoor unit
Wall-mounted
6.4
7.4
44(58)
44(58)
1-220 / 240-50
250V-10 / 16A
760 x 410 x 147
29.9 x 16.1 x 5.8
15
-
-
Turbo-Fan
steel
60
2ROW 12STEP
CAPILLARY TUBE
RBC12054-12500
INDOOR UNIT : DB27˚C WB19˚C
INDOOR UNIT : DB32˚C WB23˚C
Outdoor unit
2.70
2.90
1.4
24
24
52(61)
52(61)
3.03
3.41
890
850
3.9
3.8
98.7
99.9
21.0
-
-
695 x 530 x 280
27.4 x 20.9 x 11.0
28.0
ø6.35 x 7
ø9.52 x 7
ø21
Rotary
-
-
Propeller
steel
25
1ROW 24STEP
280
590
OUTDOOR UNIT : DB35˚C WB24˚C
OUTDOOR UNIT : DB43˚C WB26˚C