OPERATION AND FUNCTIONS
3. Water-Input MODE
1) Convert of Water-Input Mode After Ice Drop:
Water-Input Valve Open.
2) Flow Sensor Error: Water-Input is Controlled by Time
3) Veriable Factor Value : Using for A/S Steps
Flow Sensor Normal Operation : Flow Pulse Value sets "238"
!
(Water input by Time -: Maximum Water Inut Time => 15 sec.
Flow Sensor error : Water input time => 5.5 sec.
@
Water-Input Confirm MODE
4.
I-S Temp. Rising Value with RT-S Temp. Mode after 5 min. : Estimate of Water Input
RT-S
I-S
CONTENTS
START
Inlet value ON
Water input pulse Count=0
1 Sec passed after inlet
value on?
Y
Water input pulse >10
Y
Water input pulse >target pulse
N
N
time> target time
Y
Inlet value off
STOP
7
~13
~19
C
C
C
-10
-9
-8
C
C
C
N
N
Flow-Sensor Error mode
Y
~29
~39
39
C
C
C
-7
-6
-5
C
C
C
38
REMARKS