Conversion To LP Gas
INSTRUCTIONS FOR CONVERTING RANGE FROM
NATURAL GAS TO LP GAS
Determine the combination of top burners that are featured on your range.
Identify the parts you need from this kit to complete the L.P. conversion. When
burners are converted from natural to L.P. the BTU ratings are as follows:
Top burner
Oven Burner
Oven Broiler
Griddle
Quantity
Part Description
1
LP Conversion kit label
1
Instruction for converting range to LP Gas
1
LP Conversion Label
6
Orifice - Top Burner, #58
6
Orifice - Simmer Burner, .46mm
1
Orifice - Oven Burner, #55
1
Orifice - Oven Broiler, #56
1
Orifice - Griddle, #55
6
Main burner bypass jet, blue ring
6
Simmer burner bypass jet
*Note: For operation at elevations above 2000 ft., appliance rating shall be reduced
at a rate of 4 percent for each 1000 ft. above sea level
I M P O R
I M P O R
I M P O R T T T T T A N T
I M P O R
I M P O R
After replacing the natural gas to LP orifices, be sure to keep the original factory
installed natural gas orifices for future range conversion back to natural gas. The
factory orifices are marked with the following: Top Burners 165; Oven Burner 226; Oven
Broiler 185; Griddle 206; Main Burner Bypass Jet; Simmer Bypass Jet
15,000 BTU L.P. Gas
22,000 BTU L.P. Gas
16,500 BTU L.P. Gas
18,500 BTU L.P. Gas
A N T