4. Remove the T-15 Torx screw from each side of
the outer door panel.
5. Separate the outer door assembly from the
inner door.
To replace the outer door assembly of the upper
oven door on PS978:
1. Separate the outer door assembly from the
inner door. (See To remove the outer door
assembly of the upper oven door on PS978,
this section.)
2. Place the outer door assembly handle side
down on a protective surface.
3. Peel back the refl ective tape that is attached to
the heat shield.
4. Remove the 1/4-in. hex-head screw and the
heat shield from the outer door assembly.
Tape
– 27 –
5. Remove the six 1/4-in. hex-head screws (3 from
each side) that attach the handle to the outer
door assembly.
6. Remove four 1/4-in. hex-head screws that
attach each side brace to the outer door panel.
Side Brace
7. Peel back the refl ective tape and slide the outer
door glass down to clear the 8 retaining tabs.
Tabs
Tape