Troubleshooting; Specifications; Before Returning For Repairs; Replacement Parts - Schumacher Electric XI14 Owner's Manual

Power converter converts 12v dc battery power to 120v ac household power
Table of Contents

Advertisement

Available languages

Available languages

PROBLEM
LEDs do not light,
or converter does
not function.
Maximum Continuous Output ..........................................................140 Watts
Surge Capability (0.1 second) .........................................................280 Watts
No Load Current Draw ........................................................................ <0.25A
Input Voltage Range ..............................................................10.5V-15.5V DC
Output Voltage Range ............................................................... 120V±5% AC
Optimum Efficiency ..................................................................................85%
or call 1-800-621-5485, Monday-Friday 7:00
For REPAIR OR RETURN, contact Customer Service at 1-800-621-5485. DO
NOT SHIP UNIT until you receive a RETURN MERCHANDISE AUTHORIZATION
(RMA) number from Customer Service at Schumacher Electric Corporation.
Replacement fuses can be purchased at most electronic component retailers.

TROUBLESHOOTING

POSSIBLE CAUSE
Poor contact at terminals.
Blown fuse.
Converter has shut down.

SPECIFICATIONS

BEFORE RETURNING FOR REPAIRS

For information about troubleshooting,
contact customer service for assistance:
services@schumacherelectric.com
www.batterychargers.com

REPLACEMENT PARTS

REASON/SOLUTION
Unplug and reinsert the
12 volt plug.
Replace the fuse.
See LED INICATOR AND
SHUTDOWN PROTECTION
section.
am
• 8 •
to 5:00
CST
pm

Advertisement

Table of Contents
loading

Table of Contents