In line with the company’s policy of continual product improvement, the aesthetic and dimensional characteristics, technical data and accessories of this appliance may be changed without notice. CONTENTS GENERAL INFORMATION Conformity And Range The Instructions Befor Use Name Of The Parts Technical Data Outdoor Unit Working Temperature Range Electrical Connections...
THE INSTRUCTIONS BEFORE USE GENERAL INFORMATION WARNING When having a burning smell Never cut off or damage power The power supply must adopt or smoke, please turn off the power the special circuit that with air switch cables and control wires. If the power protection and assure it has enough cable and signal control wire were supply and contact with the service...
NAMES OF THE PARTS GENERAL INFORMATION Warning If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric shock might happen.
ELECTRICAL CONNECTIONS INSTALLER G W H D ( 2 8 ) N D 3 C O : 1. emove the handle at the right side plate of the An all-pole disconnection switch having a contact outdoor unit (one screw). separation of at least 3mm in all pole should be Remove the cable clamp, connect the power connection connected in fixed wiring.
Page 6
ELECTRICAL CONNECTIONS INSTALLER G W H D ( 2 8 ) N D 3 A O : 1. emove the handle at the right side plate of the An all-pole disconnection switch having a contact outdoor unit (one screw). separation of at least 3mm in all pole should be Remove the cable clamp, connect the power connection connected in fixed wiring.
INSTALLING THE OUTDOOR UNIT INSTALLER Location Use bolts to secure the unit to a flat, solid floor. Install the drain fitting and the drain hose (for When mounting the unit on a wall or the roof, make model with heat pump only) sure the support is firmly secured so that it cannot Condensation is produced and flows from the outdoor unit move in the event of intense vibrations or a strong...
MAINTENANCE INSTALLER Use suitable instruments for the refrigerant R410A. Do not use any other refrigerant than R410A. Do not use mineral oils to clean the unit. INSTALLATION DIMENSION DIAGRAM INSTALLER The installation must be done by trained and qualified service personnel with reliability according to this manual.
CHECK AFTER INSTALLATION INSTALLER Check Items Problems Owing to Improper Installation Is the installation reliable? The unit may drop, vibrate or make noises Has the gas leakage been checked? May cause unsatisfactory cooling (heating) effect Is the thermal insulation of the unit May cause condensation and water dropping sufficient? Is the drainage smooth?
FAULT INDICATION INSTALLER D101 Meaning D102 D103 Meaning Meaning Air exhaust protection Air exhaust protection Compressor operates Blink once Blink once Blink once frequency reducing frequncy limit Compressor high pressure protection Cooling overload frequncy Twice Twice Cooling overload frequncy limit Twice unit stop reducing...