4

INDOOR UNITS COMBINATION

MXZ-2A30VA
Indoor units
combination
Unit A
22
25
22+22
22+25
25+25
Indoor units
combination
Unit A
22
3.30
25
3.60
22+22
1.90
22+25
1.90
25+25
2.00
Cooling capacity (kW)
Unit B
2.20
2.50
1.40
1.40
1.40
1.50
1.50
1.50
Heating capacity (kW)
Unit B
1.90
2.00
2.00
NOTE: Electrical data is for outdoor unit only.
Outdoor unit
power consumption
Total
2.2
(0.9 - 3.0)
(0.120 - 0.620)
2.5
(0.9 - 3.3)
(0.120 - 0.690)
2.8
( 1.1 - 3.8)
(0.250 - 0.970)
2.9
(1.1 - 3.9)
(0.250 - 1.020)
3.0
(1.1 - 4.0)
(0.250 - 1.070)
NOTE: Electrical data is for outdoor unit only.
Outdoor unit
power consumption
Total
(kW)
0.670
3.3
(0.9 - 4.0)
(0.110 - 0.910)
3.6
0.730
(0.9 - 4.5)
(0.110 - 1.050)
3.8
0.705
(1.0 - 4.3)
(0.200 - 0.770)
3.9
0.725
(1.0 - 4.4)
( 0.200 - 0.795)
4.0
0.745
(1.0 - 4.5)
(0.200 - 0.810)
14
Current
(A)
(kW)
0.430
2.08
0.490
2.37
0.540
2.61
0.565
2.73
0.595
2.87
Current
(A)
3.24
3.53
3.41
3.50
3.60
Power
factor
(%)
90
90
90
90
90
Power
factor
(%)
90
90
90
90
90