Kenwood TM-V708A Service Manual page 44

144/440mhz fm dual bander
Hide thumbs Also See for TM-V708A:
Table of Contents

Advertisement

TM-V708A
Transmission section
Item
1. Transmission
1) Band A
frequency
FREQ.:146.000MHz
adjust
Transmission
2) Band B
FREQ.:444.000MHz
Transmission
2-1.POWER
For 1), 2) and 4), switch to
write or check
adjustment mode and
Band A
carry out the operations
for Item C.
1) POWER:LOW
FREQ.:146.000MHz
Transmission
2) POWER:MID
Transmission
3) POWER:MAX
Transmission
4) POWER:HI
Transmission
5) FREQ.:144.000MHz
FREQ.:147.975MHz
POWER:HI
Transmission
6) POWER:MID
Transmission
7) POWER:LOW
Transmission
2-2.POWER
For 1), 2) and 4), switch to
write or check
adjustment mode and
Band B
carry out the operations
for Item C.
1) POWER:LOW
FREQ.:444.000MHz
Transmission
2) POWER:MID
Transmission
3) POWER:MAX
Transmission
4) POWER:HI
FREQ.:444.000MHz
FREQ.:438.000MHz
FREQ.:449.975MHz
Transmission
44
ADJUSTMENT
Measurement
Condition
Test-
equipment
f. counter
Power meter panel
Power
meter
Ammeter
Power
meter
Ammeter
Unit
Terminal
Unit
Rear
ANT
TX-RX
Rear
ANT
Display
panel
Display
Rear
ANT
Display
panel
Display
Adjustment
Specifications/
Parts
Method
Remarks
TC1
146.000
Not Warm up the set.
±100Hz
MHz
TC300
444.000
MHz
Encoder
Write
5.0W±0.5W
[FREQ2] key
12W±1W
Check
48W or more
Encoder
1) If MAX Power is 52W or
[FREQ2] key Write
more, adjust TX power
within 50W±1W.
2) If MAX Power is between
from 48W to 52W, adjust
TX power within (MAX
Power -2W)±1W.
Check
44 ~ 60W
10 ~ 14W
3 ~ 10W
Encoder
Write
5.0W±0.5W
[FREQ2] key
12W±1W
Check
33W or more
Encoder
Write
1) If MAX Power is 37W or
[FREQ2] key
more, adjust TX power
within 35W±1W.
2) If MAX Power is between
from 33W to 37W, adjust
TX power within (MAX
Power -2W)±1W.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents